ZUE 282.130 (Fundamental Function - Ignition)

From Nefmoto

Revision as of 15:14, 29 September 2011 by MattDanger (Talk | contribs)

Jump to: navigation, search

See the funktionsrahmen for the following diagrams:

zue zue

zue dzwll


ZUE 282.130 Function Description


The ignition angle (zwgru) from the fundamental ignition angle calculation is corrected by the warm-up angle (dzwwl) and the cylinder-specific knock control angle (dwkrz), and it follows that the basic ignition angle (zwbas) is identical with the earliest possible ignition angle. This ignition angle now forms the route in to the ignition engine torque implementation (MDZW), which provides the output ignition angle (zwsol). This ignition angle is now limited to the earliest or latest possible ignition angle. The resulting ignition angle (zwist) is corrected by the phase error which gives the output ignition angle (zwout).


For back-up protection of the ignition angles, the one’s complement (i.e. inverse binary value) of zwout is calculated which forms zwoutcpl. This then becomes the input variable of the function monitor.


The cylinder bank selective ignition angle adjustment is activated via the codeword CWDZWLL = 1.

The delta ignition angle (dzwll) corresponding to B_bankl2 is added to, or subtracted from zwsol.

ZUE 282.130 Application Notes


Three interfaces are provided for the application; the RAM cell vszw and the fixed value ZWAPPL ZW enable adjustment of application tools. Engagement of the torque functions can be disabled using the codeword CWMDAPP (bit 0), so that the applied ignition angle (zwbas) can be driven directly.


Parameter


Description


CWZWBANK


Codeword for enabling cylinder-specific ignition angle offsets


FZIZWV


Factor for torque correction via cylinder-specific ignition angle adjustment


KFDZWLL


Map for delta ignition angle during idle


KLZWBSMN


Latest possible basic ignition angle


TMZIZWV


Engine temperature threshold for enabling cylinder-specific ignition angle adjustment


VZIZWV


Vehicle speed threshold for disabling cylinder-specific ignition angle adjustment


WPHN


Phase response


ZWAPPL


Application interface: ignition angle adjustment


Variable


Description


B_BANK2


Condition flag for cylinder bank 2


B_LL


Condition flag for idle


B_LLREIN


Condition flag for idle control active


B_NOZWE


Condition flag for no ignition angle intervention in the torque structure


B_SA


Condition flag for overrun fuel cut-off


B_ZWAPPL


Condition flag for ignition angle application without torque intervention


B_ZWKRA


Condition flag for ignition angle output during knock regulation


CWDZWLL


Codeword for delta ignition angle during idle active


DWKR


Cylinder-specific ignition angle retardation during knock control


DZWBANK


Cylinder bank-specific ignition angle offset


DZWOB


Delta ignition angle during overboost


DZWWL


Delta ignition angle during warm-up


DZWZK


Delta ignition angle during knock


MISOLZ_W


Indexed resulting desired torque for ignition angle intervention


MIZSOL_W


Indexed resulting desired torque for ignition angle intervention


NMOT


Engine speed


NSOL


Desired idle speed


REDIST


Actual reduction stage


RL


Relative cylinder charge


SY_REDMX


System constant: maximum reduction stage


SY_TDZW


System constant: additive ignition angle adaptation active


SY TURBO


System constant: turbocharger


SY_WMAX


System constant: earliest outputtable ignition angle


SY_WMIN


System constant: latest outputtable ignition angle


SY_ZIZWV


Text must be provided by Mrs Sauer


SZOUT_W


Closing time output


TMOT


Engine temperature


VFZG


Vehicle speed


VSTDZW


Additive ignition angle adaption


VSZW


Ignition angle correction adjusting system


WKRDY


Ignition angle retardation via dynamic knock regulation


WPHG


Ignition angle speed sensor phase correction


ZNACHANZ


Number of ignitions in overrun


ZWBAS


Basic ignition angle


ZWDLLPRT


Ignition angle pointer with delta idle ignition angle


ZWGRU


Fundamental ignition angle


ZWIST


Actual ignition angle


ZWOUT


Ignition angle output


ZWOUTCPL


One’s complement of the ignition angles for function monitoring


ZWOUTPRT


Ignition angle pointer


ZWSOL


Desired ignition angle for torque intervention


ZWSPAE


Latest ignition angle


ZWSTT


Ignition angle during start


ZWZYL1


Ignition angle for cylinder 1


ZZYLZUE


Dwell angle-cylinder counter for calculating ignitions


Personal tools