Difference between revisions of "MDZW 1.120 (Calculating Torque at the Desired Ignition Angle)"

From Nefmoto

Jump to: navigation, search
 
(2 intermediate revisions by one user not shown)
Line 1: Line 1:
           
 
 
<u>MDZW 1.120 Function Description</u>
 
<u>MDZW 1.120 Function Description</u>
 
 
    
 
    
When
+
When calculating the desired ignition angle there are three different cases:
calculating the desired ignition angle there are three different cases:
+
  
1.
+
1. Torque influence on the ignition angle active (B_zwvs = 1)
Torque influence on the ignition angle active (B_zwvs = 1)
+
 
   
 
   
2.
+
2. Switching off torque influence on the ignition angle (B_zwvs = 0, dmaufr_w&gt; 0)
Switching off torque influence on the ignition angle (B_zwvs = 0, dmaufr_w&gt;
+
0)
+
 
   
 
   
3.
+
3. Torque influences inactive (B_nozwe = 1)
Torque influences inactive (B_nozwe = 1)
+
  
 
    
 
    
<u>1.
+
<u>1. Active Torque Intervention</u>
Active Torque Intervention</u>
+
 +
The enable condition (B_zwvs) condition is set and the switch-off condition for the ignition angle intervention (B_nozwe) is false. The desired ignition angle is calculated from the torque requirement for the ignition path mizsol_w. The perturbation ramp (dmaufr_w) is zero. The requested torque mizsol_w is converted into the desired efficiency etazws. This is done by dividing by the optimum torque, which is calculated by multiplying miopt_w with the efficiency etazaist. The desired efficiency (etazws) is converted via the inverse ignition angle efficiency characteristic DZWETA into a delta-ignition angle (dzws). The difference between the optimum ignition angle zwopt and dzws gives the desired ignition angle zwsol.
  
 
    
 
    
The
+
<u>2. Switching off the Torque Influence</u>
enable condition (B_zwvs) condition is set and the switch-off condition for the
+
ignition angle intervention (B_nozwe) is false. The desired ignition angle is
+
calculated from the torque requirement for the ignition path mizsol_w. The
+
perturbation ramp (dmaufr_w) is zero. The requested torque mizsol_w is
+
converted into the desired efficiency etazws. This is done by dividing by the
+
optimum torque, which is calculated by multiplying miopt_w with the efficiency
+
etazaist. The desired efficiency (etazws) is converted via the inverse ignition
+
angle efficiency characteristic DZWETA into a delta-ignition angle (dzws). The
+
difference between the optimum ignition angle zwopt and dzws gives the desired
+
ignition angle zwsol.
+
  
 
+
When switching off the torque intervention (B_zwvz = 1®0, see %MDKOG), the desired torque mizsol_w can jump to a higher value. This positive torque perturbation must be prevented for driveability reasons. This is done by eliminating the requirement B_zwvz. A perturbation ramp dmaufr_w is reset, which initialises the amplitude of the jump and runs down to zero with a speed-dependent rate. This ramp is subtracted from the input mizsol_w and ensures a smooth transition into a state without any intervention within the timeframe. In this state B_zwvs = false, the switch-off condition for the ignition angle intervention B_nozwe is set but only after the ramp.
<u>2. Switching off the Torque
+
Influence</u>
+
  
 
    
 
    
When
+
A special case is the anti-judder feature intervention, in which B_zwvs, but not B_zwvz is set. When the anti-judder torque requirement is eliminated from input mizsol_w, there is no jump, so that the switch-off ramp in this case is not necessary.
switching off the torque intervention (B_zwvz = 1®0,
+
see %MDKOG), the desired torque mizsol_w can jump to a higher value. This
+
positive torque perturbation must be prevented for driveability reasons. This is done by eliminating the requirement
+
B_zwvz. A perturbation ramp dmaufr_w is reset, which initialises the amplitude
+
of the jump and runs down to zero with a speed-dependent rate. This ramp is
+
subtracted from the input mizsol_w and ensures a smooth transition into a state
+
without any intervention within the timeframe. In this state B_zwvs = false, the
+
switch-off condition for the ignition angle intervention B_nozwe is set but
+
only after the ramp.
+
  
 
    
 
    
A
+
<u>3. Torque Influences Inactive</u>
special case is the anti-judder feature intervention, in which B_zwvs, but not
+
B_zwvz is set. When the anti-judder torque requirement is eliminated from input
+
mizsol_w, there is no jump, so that the switch-off ramp in this case is not
+
necessary.
+
  
 
 
<u>3.
 
Torque Influences Inactive</u>
 
  
 
+
In this state, no requirement is active (B_zwvs = 0) and the ramp dmaufr_w is screened. The switch-off condition for the ignition angle intervention B_nozwe is set. In this case, the desired ignition angle zwsol for the ignition is not taken into account (c.f. %ZUE) so the calculation can be omitted.
In
+
this state, no requirement is active (B_zwvs = 0) and the ramp dmaufr_w is
+
screened. The switch-off condition for the ignition angle intervention B_nozwe
+
is set. In this case, the desired ignition angle zwsol for the ignition is not
+
taken into account (c.f. %ZUE) so the calculation can be omitted.
+
  
 
    
 
    
Line 71: Line 32:
  
 
    
 
    
The
+
The values &#8203;&#8203;are in DMAUFN are preset to give a slope of approximately 5%/sec for all engine speeds.
values &#8203;&#8203;are
+
in DMAUFN are preset to give a slope of approximately 5%/sec for all engine speeds.
+
  
                                                                                       
+
<u>Abbreviations</u>
 +
                                                                               
 
{| border="1"
 
{| border="1"
 
|-
 
|-
 
|  
 
|  
 
Parameter
 
Parameter
 
 
 
|  
 
|  
 
Description
 
Description
 
 
 
|-
 
|-
 
|  
 
|  
 
DMAUFN
 
DMAUFN
 
 
 
|  
 
|  
 
Delta torque control after engine torque intervention
 
Delta torque control after engine torque intervention
 
 
 
|-
 
|-
 
|  
 
|  
 
DZWETA
 
DZWETA
 
 
 
|  
 
|  
 
Inverse delta ignition angle efficiency
 
Inverse delta ignition angle efficiency
 
 
 
|-
 
|-
 
|  
 
|  
 
Variable
 
Variable
 
 
 
|  
 
|  
 
Description
 
Description
 
 
 
|-
 
|-
 
|  
 
|  
 
B_NOZWE
 
B_NOZWE
 
 
 
|  
 
|  
 
Condition flag: no ignition angle intervention on the engine torque
 
Condition flag: no ignition angle intervention on the engine torque
 
structure
 
structure
 
 
 
|-
 
|-
 
|  
 
|  
 
B_ZWVS
 
B_ZWVS
 
 
 
|  
 
|  
 
Condition flag for fast external ignition angle intervention on the
 
Condition flag for fast external ignition angle intervention on the
 
torque interface
 
torque interface
 
 
 
|-
 
|-
 
|  
 
|  
 
B_ZWVZ
 
B_ZWVZ
 
 
 
|  
 
|  
 
Condition flag for ignition angle intervention on the torque interface
 
Condition flag for ignition angle intervention on the torque interface
 
 
 
|-
 
|-
 
|  
 
|  
 
DMAUFR_W
 
DMAUFR_W
 
 
 
|  
 
|  
 
Delta “up regulation” torque
 
Delta “up regulation” torque
 
 
 
|-
 
|-
 
|  
 
|  
 
DZWS
 
DZWS
 
 
 
|  
 
|  
 
Delta ignition angle between zwopt and zwsol
 
Delta ignition angle between zwopt and zwsol
 
 
 
|-
 
|-
 
|  
 
|  
 
ETAZAIST
 
ETAZAIST
 
 
 
|  
 
|  
 
Actual cylinder suppression efficiency
 
Actual cylinder suppression efficiency
 
 
 
|-
 
|-
 
|  
 
|  
 
ETAZWS
 
ETAZWS
 
 
 
|  
 
|  
 
Desired ignition angle efficiency
 
Desired ignition angle efficiency
 
 
 
|-
 
|-
 
|  
 
|  
 
MIBAS_W
 
MIBAS_W
 
 
 
|  
 
|  
Indexed basic torque
+
Indicated basic torque
 
+
+
 
|-
 
|-
 
|  
 
|  
 
MIOPT_W
 
MIOPT_W
 
 
 
|  
 
|  
Optimum indexed torque
+
Optimum indicated torque
 
+
+
 
|-
 
|-
 
|  
 
|  
 
MISOL_W
 
MISOL_W
 
 
 
|  
 
|  
Indexed resulting desired torque
+
Indicated resulting desired torque
 
+
+
 
|-
 
|-
 
|  
 
|  
 
MIZSOL_W
 
MIZSOL_W
 
 
 
|  
 
|  
Indexed resulting desired torque for ignition angle intervention
+
Indicated resulting desired torque for ignition angle intervention
 
+
+
 
|-
 
|-
 
|  
 
|  
 
MIZWMN_W
 
MIZWMN_W
 
 
 
|  
 
|  
Indexed engine torque at the latest ignition angle
+
Indicated engine torque at the latest ignition angle
 
+
+
 
|-
 
|-
 
|  
 
|  
 
NMOT W
 
NMOT W
 
 
 
|  
 
|  
 
Engine speed
 
Engine speed
 
 
 
|-
 
|-
 
|  
 
|  
 
REDIST
 
REDIST
 
 
 
|  
 
|  
 
Actual reduction stage
 
Actual reduction stage
 
 
 
|-
 
|-
 
|  
 
|  
 
R SYN
 
R SYN
 
 
 
|  
 
|  
 
Synchronisation grid
 
Synchronisation grid
 
 
 
|-
 
|-
 
|  
 
|  
 
ZWOPT
 
ZWOPT
 
 
 
|  
 
|  
 
Optimum ignition angle
 
Optimum ignition angle
 
 
 
|-
 
|-
 
|  
 
|  
 
ZWSOL
 
ZWSOL
 
 
 
|  
 
|  
 
Desired ignition angle for torque intervention
 
Desired ignition angle for torque intervention
 
 
 
|}
 
|}
  
 
[[Category:ME7]]
 
[[Category:ME7]]

Latest revision as of 12:48, 22 May 2012

MDZW 1.120 Function Description

When calculating the desired ignition angle there are three different cases:

1. Torque influence on the ignition angle active (B_zwvs = 1)

2. Switching off torque influence on the ignition angle (B_zwvs = 0, dmaufr_w> 0)

3. Torque influences inactive (B_nozwe = 1)


1. Active Torque Intervention

The enable condition (B_zwvs) condition is set and the switch-off condition for the ignition angle intervention (B_nozwe) is false. The desired ignition angle is calculated from the torque requirement for the ignition path mizsol_w. The perturbation ramp (dmaufr_w) is zero. The requested torque mizsol_w is converted into the desired efficiency etazws. This is done by dividing by the optimum torque, which is calculated by multiplying miopt_w with the efficiency etazaist. The desired efficiency (etazws) is converted via the inverse ignition angle efficiency characteristic DZWETA into a delta-ignition angle (dzws). The difference between the optimum ignition angle zwopt and dzws gives the desired ignition angle zwsol.


2. Switching off the Torque Influence

When switching off the torque intervention (B_zwvz = 1®0, see %MDKOG), the desired torque mizsol_w can jump to a higher value. This positive torque perturbation must be prevented for driveability reasons. This is done by eliminating the requirement B_zwvz. A perturbation ramp dmaufr_w is reset, which initialises the amplitude of the jump and runs down to zero with a speed-dependent rate. This ramp is subtracted from the input mizsol_w and ensures a smooth transition into a state without any intervention within the timeframe. In this state B_zwvs = false, the switch-off condition for the ignition angle intervention B_nozwe is set but only after the ramp.


A special case is the anti-judder feature intervention, in which B_zwvs, but not B_zwvz is set. When the anti-judder torque requirement is eliminated from input mizsol_w, there is no jump, so that the switch-off ramp in this case is not necessary.


3. Torque Influences Inactive


In this state, no requirement is active (B_zwvs = 0) and the ramp dmaufr_w is screened. The switch-off condition for the ignition angle intervention B_nozwe is set. In this case, the desired ignition angle zwsol for the ignition is not taken into account (c.f. %ZUE) so the calculation can be omitted.


MDZW 1.120 Application Notes


The values ​​are in DMAUFN are preset to give a slope of approximately 5%/sec for all engine speeds.

Abbreviations

Parameter

Description

DMAUFN

Delta torque control after engine torque intervention

DZWETA

Inverse delta ignition angle efficiency

Variable

Description

B_NOZWE

Condition flag: no ignition angle intervention on the engine torque structure

B_ZWVS

Condition flag for fast external ignition angle intervention on the torque interface

B_ZWVZ

Condition flag for ignition angle intervention on the torque interface

DMAUFR_W

Delta “up regulation” torque

DZWS

Delta ignition angle between zwopt and zwsol

ETAZAIST

Actual cylinder suppression efficiency

ETAZWS

Desired ignition angle efficiency

MIBAS_W

Indicated basic torque

MIOPT_W

Optimum indicated torque

MISOL_W

Indicated resulting desired torque

MIZSOL_W

Indicated resulting desired torque for ignition angle intervention

MIZWMN_W

Indicated engine torque at the latest ignition angle

NMOT W

Engine speed

REDIST

Actual reduction stage

R SYN

Synchronisation grid

ZWOPT

Optimum ignition angle

ZWSOL

Desired ignition angle for torque intervention