ME9 Abbreviations in English (T)
From Nefmoto
|
T6D0183 |
DFP_XYZ f. OBDMID 01 TID 83 f. service $06 via CAN |
|
T6D0184 |
DFP_XYZ f. OBDMID 01 TID 84 f. service $06 via CAN |
|
T6D0201 |
DFP_XYZ f. OBDMID 02 TID 01 f. service $06 via CAN |
|
T6D0202 |
DFP_XYZ f. OBDMID 02 TID 02 f. service $06 via CAN |
|
T6D0205 |
DFP_XYZ for OBDMID $02 TID $05 for service $06 via CAN |
|
T6D0207 |
DFP_XYZ f. OBDMID 02 TID 07 f. service $06 via CAN |
|
T6D0208 |
DFP_XYZ f. OBDMID 02 TID 08 f. service $06 via CAN |
|
T6D0281 |
DFP_XYZ f. OBDMID 02 TID 81 f. service $06 via CAN |
|
T6D0282 |
DFP_XYZ f. OBDMID 02 TID 82 f. service $06 via CAN |
|
T6D0283 |
DFP_XYZ f. OBDMID 02 TID 83 f. service $06 via CAN |
|
T6D0286 |
DFP_XYZ for OBDMID $02 TID $86 for service $06 via CAN |
|
T6D21FO |
DFP for OBDMID factor oxygen entry of catalyst diagnosis |
|
T6D39TESG |
DFP for OBDMID $39 TID $80 rough leak gradient check (tank leak diagnosis) |
|
T6D3CEONV |
DFP for OBDMID $3C TID $80 0.020-EVAP-Diagnosis (DEONV) |
|
T6D3DAAV |
DFP für OBDMID $3D TID $8C AAV-Diagnosis (tank leak diagnosis) |
|
T6D3DPPR |
DFP für OBDMID $3D TID (by pressure in tank) TEV-Diagnosis |
|
T6D4185 |
DFP_XYZ f. OBDMID 41 TID 85 f. service $06 via CAN |
|
T6D4281 |
DFP_XYZ f. OBDMID 42 TID 81 f. service $06 via CAN |
|
T6DA20B |
Scan tool communication mode $06, TID $0B: DFP index ignition 0 |
|
T6DA20C |
Scan tool communication mode $06, TID $0C: DFP index ignition 0 |
|
T6DA30B |
Scan tool communication mode $06, TID $0B: DFP index ignition 1 |
|
T6DA30C |
Scan tool communication mode $06, TID $0C: DFP index ignition 1 |
|
T6DA40B |
Scan tool communication mode $06, TID $0B: DFP index ignition 2 |
|
T6DA40C |
Scan tool communication mode $06, TID $0C: DFP index ignition 2 |
|
T6DA50B |
Scan tool communication mode $06, TID $0B: DFP index ignition 3 |
|
T6DA50C |
Scan tool communication mode $06, TID $0C: DFP index ignition 3 |
|
TABGDYNH |
threshold for exhaust temperature dynamic-measuring |
|
TABGL |
Time for LSU adjusting |
|
TABGMAX |
maximum allowed temperature by double injection GDI |
|
TABGMHSHK |
exhaust-gas temperature threshold for sensor heater downstream catalyst |
|
TABGS |
Time after start for LSU adjusting |
|
TABGSTGK |
threshold for exhaust temperature dynamic-measuring |
|
TABMNTUM |
engine switch off time up to cooling down for update of ambient temperature |
|
TABSMADTM |
engine switch off time up to cooling down for TMOT-diagnosis |
|
TABSTABMX |
max. stop time after which cooling temperature of exhaust gas is imprecise |
|
TABSTGENED |
|
|
TABSTHLSH |
Minimum parking time for start of LS heating diagnosis downstream kat |
|
TABSTHLSU |
Minimum parking time for repeated start of LSU heating |
|
TABSTKH |
Minimum soak time for release of catalyst heating |
|
TABSTODSP |
Minimum Engine shut down time for Display Engine Oil Low Level |
|
TABSTRILSU |
soak time for release of Ri calculation |
|
TABSTTOTRA |
Engine off max time for the initialistion of the transmission temperature model. |
|
TACTDCAHI |
Duration for which the debris clearing algorithm commanding high duty cycle |
|
TACTDCAHI |
Duration for which the debris clearing algorithm commanding high duty cycle |
|
TACTDCALO |
Duration for which the debris clearing algorithm commanding low duty cycle |
|
TACTDCALO |
Duration for which the debris clearing algorithm commanding low duty cycle |
|
TACTPCAHI |
Duration for which the high duty cycle for the Pin Cycler Algorithm is applied ( |
|
TACTPCALO |
Duration for which the low duty cycle for the stuck Pin Cycler Algorithm is appl |
|
TACTPCEHI |
Duration for which the low duty cycle for the stuck Pin Cycler Algorithm is appl |
|
TACTPCELO |
Duration for which the low duty cycle for the stuck Pin Cycler Algorithm is appl |
|
TADCAHI |
High duty cycle for the debris clearing algorithm |
|
TADCAHI |
High duty cycle for the debris clearing algorithm |
|
TADCALO |
Low duty cycle for the debris clearing algorithm |
|
TADCALO |
Low duty cycle for the debris clearing algorithm |
|
TADHMNH |
lower Temperature threshold heater diagnostic routine down stream kat |
|
TADHMNHFA |
lower Temperature threshold heater diagnostic routine down stream kat |
|
TADHMXH |
upper temperature threshold for O2 sensor heater diagnostic post catalyst |
|
TADHMXHFA |
upper temperature threshold for O2 sensor heater diagnostic post catalyst |
|
TADLLR |
intake air temperature threshold for ISC-actuator diagnosis |
|
TADMM |
1. step width (time) for engine temperature model |
|
TAFKPVDKE |
delay time for condition adaption fkpvdk in steady-state |
|
TAFSOMN |
Time delay to reset the heat quantity integrator iwmatma |
|
TAFUPSRLE |
time delay for condition adaptation fupsrl stationary |
|
TAGAT |
Time constant for torque limitation regulation |
|
TAHLL |
tans threshold for increased target speed at hot idling |
|
TAHRLSUMN |
Minimum duty cycle for diagnosis power stage |
|
TAHRLSUMX |
max. duty cycle of actuation of LSU heater |
|
TAHSOMFMN |
exhaust-gas temperature threshold for B_shab downstream catalyst |
|
TAHSOMN |
Minimum exhaust-gas temp. downstream sensor at which water still evaporates at i |
|
TAIKRBTS |
Threshold exhaust gas temperature inside manifold for component protection |
|
TAKOSLUG |
Intake air temperature threshold for antislugging action |
|
TALDRDMN |
min. PWM-ratio Waste Gate Control valve to perform diagnostic of driver circuit |
|
TALDRDMX |
max. PWM-ratio Waste Gate Control valve to perform diagnostic of driver circuit |
|
TALSUSMX |
Maximum exhaust gas temperature threshold for plausibility diagnosis |
|
TAMDOGH |
temp. threshold from exhaust temp. modell for diagnosis sensor downstream cat |
|
TAMIALU |
min. induction-air temperature for deactivating misfire-detection |
|
TAMSIGH |
threshold for exh. temp. for wiring-interruption with Ri-diagnosis downstr. cat |
|
TANDT |
threshold difference intake air temperature for hot start |
|
TANDT1 |
delta threshold intake air temperature for hot start |
|
TANFAPPL |
Applicable request of temperature for catalyst heating by spark retarding |
|
TANH |
intake air temperature - threshold warm |
|
TANH1 |
intake air temperature - threshold hot start |
|
TANHKSAO |
upper limit exhaust gas temperature downstream main catalyst |
|
TANKMN |
minimum fuel in for refuelling diagnostic |
|
TANMN |
starter activation time low limit |
|
TANMXT |
starter activation time limit depending on engine temperature |
|
TANOVMX |
max. crank time at key overwrite |
|
TANOVMX |
max. crank time at key overwrite |
|
TANSDBKVPF |
Temp. thresh. f. enabling entry E_bkvp (error BKV pump) |
|
TANSDE |
substitute value air temperature in case of fault |
|
TANSDHLSH |
Intake air temp. threshold for Ri- diagnosis downstream kat |
|
TANSKOB |
Intake-air temperature threshold for compressor shutdown |
|
TANSLFO |
intake air temperature threshold for the fan power |
|
TANSLFU |
Intake air temperature threshold for the fan power |
|
TANSMN |
intake air temperature limit (for post-start torque increase) |
|
TANSMN_UM |
Intake air temp. threshold for after-start expansion in the watchdog function |
|
TANVKBTS |
Threshold exhaust gas temperature downstream precat for component protection |
|
TANW |
Suction air temperature threshold for camshaft adjustment |
|
TANWASTMN |
min. duty cycle limit setting the cycle flag of cam shaft actuator power stage |
|
TANWASTMX |
max. duty cycle limit setting the cycle flag of cam shaft actuator power stage |
|
TANWBSA |
Maximum duty cycle during limitation for component protection (outlet) |
|
TANWBSE |
Maximum duty cycle during limitation for component protection (inlet) |
|
TANWDCKOEO |
cam control duty cycle by tester, key-on-engine-off test |
|
TANWESTMN |
min. duty cycle limit setting the cycle flag of cam shaft actuator power stage |
|
TANWESTMX |
max. duty cycle limit setting the cycle flag of cam shaft actuator power stage |
|
TANWMNLIA |
Minimum Duty Cycle slow I-Part Cam Controller (exhaust) |
|
TANWMNLIE |
Minimum Duty Cycle slow I-Part Cam Controller (Intake) |
|
TANWMNSIA |
Mimimum Duty Cycle fast I-Part Cam Controller (outlet) |
|
TANWMNSIE |
Mimimum Duty Cycle fast I-Part Cam Controller (Intake) |
|
TANWMXLIA |
Maximum Duty Cycle slow I-Part Cam Controller (exhaust) |
|
TANWMXLIE |
Maximum Duty Cycle slow I-Part Cam Controller (Intake) |
|
TANWMXSIA |
Maximum Duty Cycle fast I-Part Cam Controller (outlet) |
|
TANWMXSIE |
Maximum Duty Cycle fast I-Part Cam Controller (Intake) |
|
TANWPCAHI |
High Duty Cycle for the Pin Cycler Algorithm (exhaust) |
|
TANWPCALO |
Low Duty Cycle for the Pin Cycler Algorithm (exhaust) |
|
TANWPCEHI |
High Duty Cycle for the Pin Cycler Algorithm (exhaust) |
|
TANWPCELO |
Low Duty Cycle for the Pin Cycler Algorithm (exhaust) |
|
TANWREFA |
Min. duty cycle for control of reference position outlet camshaft |
|
TANWREFE |
Min. duty cycle for control of reference position inlet camshaft |
|
TANWRMAXA |
Maximum Duty Cycle Cam Controller (Exhaust) |
|
TANWRMAXE |
Maximum Duty Cycle Cam Controller (Intake) |
|
TANWRMINA |
Minimum Duty Cycle Cam Controller (exhaust) |
|
TANWRMINE |
Minimum Duty Cycle Cam Controller (Intake) |
|
TANWRMPA |
Gradient duty cycle outlet camshaft over ramp during CU run-out |
|
TANWRMPE |
Gradient duty cycle inlet camshaft over ramp during CU run-out |
|
TAOFMSNDKE |
Time constant for determining leakage air adaptation throttle valve steady |
|
TAPBRINT |
ab der pslm-psdss für Setzen von E/Z_lzsr ausgewertet wird |
|
TAPVLTM |
threshold soak time for EKP-lead time |
|
TARA |
temperature threshold intake air |
|
TARA |
temperature threshold intake air |
|
TAREIN |
lockup time for anti-jerk function |
|
TASHMN |
temperature on the sensor for adequate sensor heating |
|
TASHS |
threshold intake air temp.for trigg.of TLRHS-blocking time LC during hot start |
|
TASTKOSLUG |
Intake air temperature for antislugging action |
|
TATEGMX |
Maximum PCV duty cycle for pulsed PCV activation |
|
TATELL |
tans-threshold for canister purge control with B_ll = 1 |
|
TATEMSN |
characteristic line of the PCV duty-cycle depending on the desired mass-flow |
|
TATMDIFF |
temperature limit for changeable ambient conditions before start |
|
TATMKRSA |
Exhaust gas temperature in manifold during fuel cutoff |
|
TATMRTPA |
Time delay to reset the heat quantity integrator iwmatma |
|
TATMRTPFK |
Time delay to reset the heat quantity integrator iwmatmf |
|
TATMRTPK |
Time delay to reset the heat quantity integrator iwmatmk |
|
TATMSTI |
initial value tabgm, tkatm at power fail |
|
TATRIHKS |
desired value exhaust temperature in main catalyst |
|
TATRVHKS |
desired value exhaust temperature upstream main catalyst |
|
TAUIDEC |
Time constant of integral part decay at one-sided boundary control |
|
TAVDCMN |
min. exhausttemp. to activate the diagnosis ""schwacher Heizer"" |
|
TAVDKERLX |
substitution value for air temperature upstream throttle for calculating the max |
|
TAVHKBTS |
Threshold exhaust gas temperature upstream maincatalyst for component protection |
|
TAVHKEMN |
Start temperature of main catalyst |
|
TAVHKSAO |
upper limit exhaust gas temperature upstream main catalyst |
|
TAVMX |
Delay of the DLSVE after heater on\ or after B_SA |
|
TAVOLMN |
Min. exhaust gas temperature to activate general oxygen sensor diagnosis |
|
TAVROBTS |
Threshold exhaust gas temperature inside pipe upstream close-coupled catalyst fo |
|
TAVSOMN |
Minimum exhaust-gas temp. upstream pre-catalyst at which water still evaporates |
|
TAVVKBTS |
Threshold exhaust gas temperature upstream precatalyst for component protection |
|
TAVVKBTSH |
Hard threshold: overheating pre-catalyst |
|
TAVVKBTSW |
Soft threshold: overheating pre-catalyst |
|
TAVVKEMN |
catalyzer light off temperature of precatalyst |
|
TAVVKGEMN |
Start temperature of Washcoat Only Kat |
|
TAVVKSAO |
upper limit exhaust gas temperature before pre catalyst |
|
TBACCSSRYS |
debounce time for switch off accessory |
|
TBAU1MX |
Maximum time for 1st phase of operating mode switch |
|
TBAU2MXN |
Maximum time for 2nd phase of operating mode switch |
|
TBAU3MX |
Maximum time for 3rd phase of operating mode switch |
|
TBHD |
blockheater-detection: minimum time duration for detection-bit |
|
TBKVP |
time for evacuation by brake booster pump |
|
TBLOCKENG |
Time period after crancking to detecting a blocked engine |
|
TBLOCKENG |
Time period after crancking to detecting a blocked engine |
|
TBLWSOFF |
switch-off de-bouncing brake lamp switch |
|
TBLWSON |
switch-on de-bouncing brake lamp switch |
|
TBPVACMN |
The minimum time to wait between Phase 1 and Phase 2 |
|
TBRKINTINV |
|
|
TBRLLSR |
delay time break (let off) for leak in the manifold |
|
TBRTLSR |
delay time break (step on) for leak in the manifold |
|
TBRWSOFF |
switch-off de-bouncing brake switch |
|
TBRWSON |
switch-on de-bouncing brake switch |
|
TBSNPB |
|
|
TBSNPV |
|
|
TC6CTHM |
mode 6: component ID for diagnosis coolant water thermostat |
|
TCCMPCODE |
TCCM P-Code (uncertain fault entry) |
|
TCCYL |
Delta time for change of cyl. during transition mode |
|
TCJ840NLOF |
waiting time until DC/DC converter CJ840 in switch off mode get off |
|
TCJ840OFF |
waiting time until DC/DC converter CJ840 is switch off |
|
TCLUTLRNRE |
learning time for learning clutch pedal released position |
|
TCMPCODE |
TCCM P-Code (uncertain fault entry) |
|
TCOOLMN |
Min. coolant temperarure to be sure that the engine has warmed up |
|
TCPPLRNDEC |
filter time constant for decreasing the learned value |
|
TCPPLRNINC |
filter time constant for increasing the learned value |
|
TCPPLRNST |
filter time constant for detection of clutch pedal position being stable |
|
TCREXEN |
time to crank that extended crank time is activated |
|
TCTFA1 |
time constant for lowpass filter of tfa1lin |
|
TCTFA2 |
time constant for lowpass filter of tfa2lin |
|
TCWDKCTRMX |
max. time for device control DCPIDCM message monitoring |
|
TCWTFA1 |
time constant for lowpass filter of wtfa1_w |
|
TCWTFA2 |
time constant for lowpass filter of wtfa2_w (SY_TFAKON > 0) |
|
TDABGLST |
Delay enable adjustment after cranking |
|
TDAKEOFF |
switch off time for cond. cooling down after continuously dismatching area |
|
TDAPBRINT |
delay of B_apbrint |
|
TDASHTIP |
Delay time of end of start condition for tip-in dashpot |
|
TDBBKVP |
turn-on delay of B_bkvp for diagnosis |
|
TDBBNVHFM |
debounce time air-mass meter voltage supply |
|
TDBHFMPLQ |
debounce time for air-mass meter plausibility bit quantisation changed |
|
TDBHV |
blockheater-detection: maximum time duration for fuel enrichment |
|
TDBKLOFF |
switch off time for cond. radiation power after continuously dismatching area |
|
TDBKVFGABG |
Time delay after bit B_bkvmsisr for enabling of throttle adaption |
|
TDBKVKOMAB |
delay time for demand switch off air-conditioner compressor |
|
TDBKVNKHAB |
delay time for demand of idle speed for catalyst heating cut off |
|
TDBKVNWAB |
delay time for camshaft lobe control |
|
TDBKVP |
delay of bit B_pbkvmn with sufficent manifold air pressure |
|
TDBKVSTED |
turn-on delay brake booster pump after end of start |
|
TDBKVSTEND |
turn-on delay brake booster pump after end of start |
|
TDBLKHTR |
time-intervall for blockheater-detection in %DTCWCS |
|
TDBLKHTRTA |
time-window for blockheater-detection |
|
TDBRSCAN |
Time for timeout detection CAN interface bracke signal |
|
TDBSPER |
Debounce time for error detection from B_bspstat |
|
TDBSPHEAL |
delay for healing of errors |
|
TDBSPWK |
Delay time for weak short detection |
|
TDBTSFAWUHO |
|
|
TDBZHDEV |
debouncing time booster time error powerstage HDEV |
|
TDCAN1 |
time for error detection ""CAN Error passiv"" |
|
TDCAN3 |
time for error detection ""CAN BUS off"" |
|
TDCANH |
time for error healing CAN |
|
TDCBTAL |
Maximum deactivation time for MD with low fuel |
|
TDCCGW |
Time for timeout detection CAN interface Gateway |
|
TDCCGW1 |
|
|
TDCCGW2 |
|
|
TDCCGW3 |
|
|
TDCCGW4 |
|
|
TDCCPDIS |
CAM Phaser device control disable time after timeout |
|
TDCCPEN |
CAM Phaser device control enable timeout |
|
TDCEEVOFF |
device control: OFF-time injector flow test |
|
TDCEEVON |
device control: ON-time injector flow test |
|
TDCEKP |
Device Control: maximum fuelpump turn on time |
|
TDCEKPN |
Device Control: maximum fuelpump turn on time and engine running |
|
TDCEV |
initial value for timer device control fuel inj. #n |
|
TDCGENL |
max. operation time for device control of genrator L-Terminal |
|
TDCMONTIM |
initial value for device control generic timer |
|
TDCNEVMN |
device control: min. engine-running-time between two injector flow tests |
|
TDCNOLU |
Debouncing time of Display limp home mode active via GMLAN / CLASS2 |
|
TDCNWSDIS |
KOEO disabling timer |
|
TDCNWSEN |
KOEO enabling timer |
|
TDCOMHDEV |
|
|
TDCWGCON |
max. operation time for device control of waste gate |
|
TDDANWS |
Distortion time for outlet cam control diagnosis enable in end positions |
|
TDDBKVP |
time to evacuate the pressure delta DPBKVP with pump |
|
TDDDSBKV |
dechatter time brake booster pressure sensor fault recogniziation because of el. |
|
TDDEDBKVP |
maximum on-time of brake booster pump |
|
TDDENWS |
Distortion time for outlet cam control diagnosis enable in end positions |
|
TDDFAC |
Waiting time before recognition of AC pressure sensor default |
|
TDDFBKV |
dechatter time brake booster pressure sensor fault recogniziation |
|
TDDFPBKVR |
dechatter time brake booster pressure sensor fault recogniziation |
|
TDDFUUGD |
dechatter time for ambient pressure sensor fault recognization |
|
TDDHBKV |
dechatter time of setting cycle flag |
|
TDDHDEVOER |
delay time error detection DHDEVO |
|
TDDLAHIO |
Time constant for lowpass to calculate predicted offset off LSU |
|
TDDLAHIO |
Time constant for lowpass to calculate predicted offset off LSU |
|
TDDLDRA |
time for low pass filter from boost pressure deviation |
|
TDDPTETA |
time constant for detection of refueling process |
|
TDDSNO |
threshold to avoid fault diagnosis, air in System |
|
TDDSR |
dechatter time for manifold pressure sensor fault recognization |
|
TDDSTCON |
debouncing time for AAV-opening at tank pressure sensor |
|
TDDSTD |
Debounce time for check of tank pressure sensor for drift |
|
TDDSTEN |
time or enalbe of tank pressure sensor check (plaus and drift) |
|
TDDSTPL |
Time for plaus error for tank pressure sensor |
|
TDDSTR |
debouncing time for fault detection tank pressure sensor (rationality check) |
|
TDDSTW |
debouncing time for fault detection tank pressure sensor |
|
TDDSUVR |
Turn on delay diagnosis dump valve |
|
TDDTEVFGAB |
Time delay after %DTEV for enabling of throttle adaption |
|
TDDU |
dechatter time for ambient pressure sensor fault recognization |
|
TDDVD |
dechatter time for pressure sensor upstream throttle valve fault recognization |
|
TDDVEEOL |
Debounce time for open load error of the DV-E power stage |
|
TDEBFMOD |
time after end of start to leave state after initial fuelling |
|
TDEGFE |
Time delay for setting the MIN/MAX fault or healing |
|
TDEHFMPL |
debounce time for plausibility fault detection air-mass meter |
|
TDEHFMSG |
debounce time for signal fault detection air-mass meter |
|
TDEISSTE |
|
|
TDEKPON |
delay time EKP-pre run |
|
TDELTFA |
Debouncing time for enabling the electrical diagnosis of the intake air temperat |
|
TDEPSRR |
Tim delay for manifold pressure range check healing |
|
TDEPUR |
Delay for healing, min-, max, sig-error from ambient pressure continuous check |
|
TDFENWVPA |
Time delay for error entry in DFP_NWVPA(2) |
|
TDFENWVPE |
Time delay for error entry in DFP_NWVPE(2) |
|
TDFGADPS |
time delay for enabling of adaption of the suction pipe model |
|
TDFGINI |
time delay for initialize of the adjustments with neutral values |
|
TDFGRH |
delay time for cruise control lever diagnosis verified |
|
TDFGRHEP |
delay time for cruise control lever diagnosis (healing path) |
|
TDFGRHHP |
delay time for cruise control lever diagnosis (error path) |
|
TDFGRHRS |
delay time for cruise control resume-switch diagnosis (error path) |
|
TDFGRHSS |
delay time for cruise control set-switch diagnosis (error path) |
|
TDFPDMNI |
initialization value min. period duration in msec |
|
TDFPDMXI |
initialization value max. period duration in msec |
|
TDFRMXF |
time constant for low pass filtering of mixture deviation |
|
TDGENE |
delay time failure verification powerstage diagnosis alternator |
|
TDGSMX |
maximum length of time monitoring mkgs |
|
TDHDRH |
Time constant healing debounce E_HDR |
|
TDHDRMN |
Time constant fault debounce min-error HDR |
|
TDHDRMNSU |
Debouncing time low rail pressure |
|
TDHDRMNTAL |
Debouncing time min-error HDR when tank level is low |
|
TDHDRMX |
Time constant fault debounce max-error HDR |
|
TDHDRMXEN |
Time constant fault debounce max-error HDR |
|
TDHDRNPL |
Time constant fault debounce npl-error HDR |
|
TDHDRNPTAL |
Debouncing time npl-error HDR when tank level is low |
|
TDHDRSIG |
Time constant fault debounce sig-error HDR |
|
TDHDVST |
|
|
TDHEALEIS |
|
|
TDHEHFME |
Debounce time for resetting of B_ehfmfe |
|
TDHKODL |
time to reset integral |
|
TDHOEFAWUHO |
|
|
TDHRMX |
Max. processing time for main relay diagnosis |
|
TDHROFF |
waiting time main relay off |
|
TDHRON1 |
|
|
TDIAGMX |
The elapsed time allowed to execute the EONV Diagnostic |
|
TDIAGMX |
The elapsed time allowed to execute the EONV Diagnostic |
|
TDIAGMX |
The elapsed time allowed to execute the EONV Diagnostic |
|
TDIDSSU |
Delay time till initialisation of ambient pressure value with measured intake ma |
|
TDIFEONVMX |
max. temperature-difference for EONV diagnosis |
|
TDIFKH |
Mimimal absolute difference (tans - tmst) for detection of repeated cranking |
|
TDIFMX_UM |
Max. deviation of the sum of time differences betw. TPU and CPU in the FU |
|
TDISFP |
Time until shut down the fuel pump after a crash |
|
TDISINJ |
Time until shut down the injectors after fuel pump has been disabled after a cra |
|
TDISTCTRST |
reset-time for odometer information |
|
TDKHAKHN |
Delay time in wich increased idle speed is required if B_kha is set without B_kh |
|
TDKHFAWUHO |
Delay time catalyst heating for operation mode ""high overlap"" |
|
TDKLAGDE |
Time delta for clearing of fault counter with DK setpoint/actual comparison |
|
TDKNACH |
time during run after untol zero current DK stabilizes in NLP |
|
TDKPAW |
time for throttle-valve potentiometer selection |
|
TDKPEOFF |
Debouncing time for diagnosis fuel pump relay power stage (EKP = OFF) |
|
TDKPEON |
Debouncing time for diagnosis fuel pump relay power stage (EKP = ON) |
|
TDKUPNOG |
Delay time after gear change until another gear change detection is possible |
|
TDLAKAD |
Control-down time of lamka_w for controlled emptying of the catalyzer |
|
TDLAKAU |
Control-up time of lamka_w for controlled emptying of the catalyzer |
|
TDLBTSSA |
Time for transient of lambda from ignited overrun to release of fuel cut-off |
|
TDLDRAM |
time constant low pass filter for filtered boost control deviation |
|
TDLFTA |
Delay time after end of start for tans-depending fan request |
|
TDLKHNUM |
Time delay for possible error detection during catalyst heating. |
|
TDLLFG1 |
Time delay for setting the condition diagnosis of ISC-actuator |
|
TDLLR |
Time delay for setting the condition diagnosis of ISC-actuator |
|
TDLLRMN |
Time delay before storing error of closed ISC-actuator |
|
TDLLRMNKH |
Time delay before storing error of closed ISC-actuator during catalyst heating |
|
TDLLRMX |
Time delay before storing the error ISC-actuator open |
|
TDLLRMXKH |
Time delay before storing the error ISC-actuator open during catalyst heating |
|
TDLLRNF |
Time delay before storing ISC-actuator with no error |
|
TDLLRNFKH |
Time delay before storing ISC-actuator with no error during catalyst heating |
|
TDLLRNUM |
Time delay for possible error detection. |
|
TDLRHAFTMX |
Resting time for activation of the static friction routine |
|
TDLRPIDC |
Timestep for decrementing of dlrpidc |
|
TDLRPIDMX |
Max. time for PWM pulse duty factor of the DLR at temp. UMA adapt. |
|
TDLSUFTFA |
Time threshold for debouncing of fuel trim diagnosis in case of short trip |
|
TDLSUFTMX |
Time threshold for debouncing of fuel trim diagnosis |
|
TDLSUOFFA |
minimum time to confirm plausibility error with condition B_lrhk=true and B_rluo |
|
TDLSUOFMX |
minimum time to confirm plausibility error with condition B_lrhk=true and B_rluo |
|
TDLZSR |
debounce time for error path leak to manifold |
|
TDMDTAL |
Delay time for MD switch-off after end of start with low fuel |
|
TDMFB |
time for diagnosis to detect fault in MIL-Auxiliary control |
|
TDMFBSA |
Time constant PT1 filter for transition to fuel cut-off |
|
TDMFBWE |
Time constant of PT1 filter for transition from fuel cut-off |
|
TDMFWEMI |
filter-time constant at hard fuel cut-in |
|
TDMKOW |
debounce time after torque reserve: ac-clutch |
|
TDMLHFM |
Delay time for setting the bit B_hfm |
|
TDMLSDS |
time after clutch was applied with changed LSD triggering |
|
TDMLST |
debounce time fault detection air-mass meter during start |
|
TDMODW |
Timeconstant filter torque-loss-adaptation at mode transition |
|
TDMRESLL |
Inhibition time for the increased torque reserve after engine start |
|
TDMSDKS |
Time delay for the bit B_fkmsdks |
|
TDMSVE |
dechatter time |
|
TDMSVEH |
Debounce duration for healing (MSV output stage diagnosis) |
|
TDMWRLSTA |
time delay mode change rl-stationary |
|
TDNDTHMF |
time delay to enable thermostat monitoring below engine speed limit |
|
TDNDTHMS |
time delay to disable thermostat monitoring above engine speed limit |
|
TDNNPTMF |
time delay to enable tmot plausibility check below engine speed limit |
|
TDNNPTMS |
time delay to disable tmot signal plausibility check above engine speed limit |
|
TDNOMR |
Turn-on delay for detection that spark retard for catalyst heating is not poss. |
|
TDNSTKHN |
Time after crank up: require incresaed idle speed while cat. heating |
|
TDNSUB |
time period for battery after start |
|
TDNSUBR |
|
|
TDNWFAWUHO |
Delay time cam transient deviation for operation mode ""high overlap"" |
|
TDNWSP |
Time delay for the checking of the camshaft shift |
|
TDNWSPA |
Time delay for the checking of the actual camshaft shift |
|
TDNX |
Debouncing time fault type max.: critical engine speed |
|
TDOHDRMX |
delay time engine cutoff at fault ""full delivery"" |
|
TDPAKL15 |
debounce time for pressure sensor alignment after Kl15 off |
|
TDPBKVMN |
delay time for condition brake booster without enough vaccum |
|
TDPBKVMNP |
delay time for condition brake booster without enough vaccum for BKV-pump |
|
TDPFPVLLK |
Time for which the boost pressure has to be (almost) free of pulsations to reset |
|
TDPLANT |
minimum time for engine run without misfiring |
|
TDPLPSR |
Time constatn for delay of manifold pressure sensor plausibility |
|
TDPLPUI |
delay for condition ambient pressure plausible |
|
TDPLPVDI |
Time constatn for delay of pressure sensor upstream throttle plausibility |
|
TDPOELNMOT |
debouncing time for nmot used by oil pressure switch diagnosis |
|
TDPOELSOFF |
debouncing time for oil pressure switch off-diagnosis |
|
TDPOELSON |
debouncing time for oil pressure switch on-diagnosis |
|
TDPOWSUP |
debounce time for 5V power supply diagnosis |
|
TDPRHOMHMM |
delay time for release of ps-controller after changing from HOM in strat. mode |
|
TDPRISTFT |
Minimum filter time to consider the rail pressure as stable |
|
TDPRMXRQT |
Max. time for exceeding max. pressure during tester control of mass flow valve |
|
TDPRNSWLAA |
rail pressure for after start and warm-up correction activation, delay time |
|
TDPRNSWLAD |
rail pressure for after start and warm-up correction de-activation, delay time |
|
TDPSLMDS |
time constant for low pass fil. of difference bet. mod. and meas. man. pres. |
|
TDPSRRG |
Time constant for delay of electric valid manifold pressure sensor |
|
TDPSXSFIL |
delay time of psxsfil_w |
|
TDPURE |
reset time during changes of the ambient pressure |
|
TDPUSG |
delay for condition ambient pressure signal valid |
|
TDPVDSG |
Time constant for delay of electric valid pressure sensor upstream throttle |
|
TDPVFZMX |
Delay before taking over a change bigger than DPVFZMX |
|
TDREJECT |
Delay-Time to enable cutoff-cylinder |
|
TDREPFSA |
delay time healing error condition driving state via pin off |
|
TDREPFSE |
delay time healing error condition driving state via pin on |
|
TDRLLRHKX |
debouncing time for delta-rl condition: deactivation I part |
|
TDRLMXLAM |
time delay for resetting of the max. selection rl via desired Lambda |
|
TDRLRLPMAX |
Debounce time for steady state condition of delta of rl and rlp |
|
TDRTNWDA |
Timer for retriggering at pending deviation |
|
TDRTNWDE |
Timer for retriggering at pending deviation |
|
TDSAFGABGL |
Time delay after Bit B_sa for enabling of throttle adaption |
|
TDSCNHTFA1 |
stuck-check TFA1: maximum allowed time-duration outside high-phase |
|
TDSCNLTFA1 |
stuck-check TFA1: maximal allowed time duration outside low-phase |
|
TDSEPFSA |
delay time setting error condition driving state via pin off |
|
TDSEPFSE |
delay time setting error condition driving state via pin on |
|
TDSOHVTD |
|
|
TDSRLMX |
time delay for switch-over from main to secondary load signal |
|
TDSTAECALC |
turn on delay B_desta |
|
TDSTCHTFA1 |
stuck-check TFA1: minimum necessary time-duration for hig-phase-cycle |
|
TDSTCLTFA1 |
stuck-check TFA1: minimum necessary time-duration for low-phase cycle |
|
TDSTDTETK |
Delay time after filling detection for check of tank pressure sensor for drift |
|
TDTAPLMDS |
delay DTEV for enable adaptation pslm-pdss |
|
TDTCSOP |
time delay CAN: TCS OP |
|
TDTCWCS |
time point for diagnosis %DTCWCS |
|
TDTED |
time out for detection of tight purge system |
|
TDTERXC |
virtual CPV diagnosis time during idle and stand still for readiness override wi |
|
TDTEUAMX05 |
maximum duration of vacuum decay (0.5-mm-check) |
|
TDTFA1 |
debonce time for error detection (min/max) for intake air temperature sensor tfa |
|
TDTFA1HL |
debounce time for error-healing of intake air temperature sensor tfa1 |
|
TDTFA1HSC |
High-Side-Check TFA1: debounce-time for physical diagnosis enabling |
|
TDTFA1HSER |
high-side-check TFA1: debounce-time for error-entry |
|
TDTFA1HSHL |
high-side-check TFA1: debounce time for error-healing |
|
TDTFA1JT1 |
Jump-Check intake air temperature sensor tfa1: debounce time 1 (SY_TFAJEC > 0) |
|
TDTFA1JT2 |
Jump-Check intake air temperature sensor tfa1: debounce time 2 (SY_TFAJEC > 0) |
|
TDTFA2 |
debounce time for error-detection (min/max) of intake air temperature sensor tfa |
|
TDTFA2HL |
debonce time for healing of intake air temperature sensor tfa2 (SY_TFAKON > 0) |
|
TDTFA2JT1 |
Jump-Check of intake air temperature sensor tfa2: debounce time (SY_TFAKON > 0 a |
|
TDTFA2JT2 |
Jump-Check intake air temperature sensor tfa2: debounce time 2 (SY_TFAKON > 0 an |
|
TDTFA2PLE |
plausibility-check TFA2-sensor: debounce-time for enabling diagnosis |
|
TDTFA2PLER |
plausibility-check of TFA2-sensor: debounce-time for error-entry |
|
TDTFA2PLHL |
plausibility-check of TFA2-sensor: debounce-time for healing |
|
TDTFACS |
time-delay for calculating %DTFACS |
|
TDTHM |
debouncing time for engine coolant thermostat monitoring |
|
TDTLDFSTV |
delay time for information ""fuel level valid"" in driving distance debouncing |
|
TDTLIN |
time window for linearisation check for tank leakage diagnosis |
|
TDTM |
debounce time fault detection, engine temperature sensor |
|
TDTME |
TMOT error detection/time effrective from substitute value TMOT = TANS |
|
TDTMEF |
Delay time after fan fault (tmhsrc enabling of the operating range) |
|
TDTMHE |
Delay time after fault detection (diagnosis ""high side check"") |
|
TDTMHZ |
Delay time after enabling/healing (diagnosis ""high side check"") |
|
TDTMMA |
delay time load value engine temperature model |
|
TDTMNPO |
debouncing time engine temperature sensor upper non plausibility |
|
TDTOL |
debouncing time (engine-) oil temperature sensor |
|
TDUB |
delay time of voltage diagnosis |
|
TDUBDFST |
|
|
TDUBEVAB |
|
|
TDUBHFM |
time of HFM-diagnosis at u < UBHFM |
|
TDV |
error detection tachometer signal / time for interrogation |
|
TDVDCA |
time delay vehicle dynamics control active |
|
TDVIVZ |
tolerance time of high deviation between actual and target velocity |
|
TDVPPM |
Debounce for bit B_vppm |
|
TDVZVI |
tolerance time of high deviation between target and actual velocity |
|
TDWNWSE |
Time delay for confirm nominal angle for camshaft |
|
TDWOTDN |
|
|
TDWOTRUP |
Monitoring time for opening throttle at wide open throttle self test |
|
TDWPOPBP |
delay time for deactivation of APS/Brake-Check using pedal gradient |
|
TDWWHMM |
time constant for change of heat transition ratio due to mode homogeneous-lean |
|
TDWWSCH |
time constant for change of heat transition ratio due to mode stratified |
|
TDZENABLE |
De-bouncing time for indication of ignition power stage diagnosis |
|
TEBBREMS |
debounce time of B_brems |
|
TEBKVKOMAB |
Debouncing time for air-conditioner compressor |
|
TEBKVNKHA |
Debouncing time for switch pressure brake booster |
|
TEBKVNWAB |
Debouncing time for camshaft lobe control |
|
TECULOCK2 |
delay time 2 for the release from IMMO |
|
TEEKPMX2 |
Maximum value for teekp - large range (0 .. 3276.75sec) |
|
TEEMRDYMAX |
max. time counter for EEPROM-mirror-ready |
|
TEFABE |
Duration diagnosis-systemtest at end of line |
|
TEFRA |
Detection time for ""FRA stable"" by exceed of diagnostic threshold |
|
TEGA |
time threshold for scan of the mixture adaptation |
|
TEHEHRLSU |
Duty time for healing of fault path HRLSU |
|
TEHRF |
Duty cycle errors in heater control |
|
TEHRLSUE |
Duty cycle for heater control of LSU for electrical error |
|
TEHRLSUZFA |
Time to prevent healing at high exhaust gas temperatures during B_fa |
|
TEHRLSUZMX |
Time to prevent healing at high exhaust gas temperatures |
|
TEIG |
time constant lowpass body temperature, tmsvm |
|
TEIRLRLSOL |
Time constants for stabalization of rl/rlsol |
|
TEIRLRLSZU |
Time constants for stabalization of rl/rlsol at rlsol<rl |
|
TEISBRECH |
Intake air temp. threshold release of breakaway funct.event throttle valve icing |
|
TENSBBLSU |
temperature threshold for common electrical error LSU |
|
TENWNADA |
Adjust. time f. unlocking the exhaust CmS for non-adapted system |
|
TENWNADE |
Adjust. time f. unlocking the intake CmS for non-adapted system |
|
TEONVAHMN |
Lower boundary of the ambient air temperature window by hot start used to enable |
|
TEONVAHMX |
Upper boundary of the ambient air temperature window by hot start used to enable |
|
TEONVAMN |
Lower boundary of the ambient air temperature window by cold start used to enabl |
|
TEONVAMN |
Lower boundary of the ambient air temperature window by cold start used to enabl |
|
TEONVAMX |
Upper boundary of the ambient air temperature window by cold start used to enabl |
|
TEONVAMX |
Upper boundary of the ambient air temperature window by cold start used to enabl |
|
TEONVDFP |
time decrease/increase in pressure after a peak needed to identify it as a overp |
|
TEONVERTMN |
minimum engine run time for EONV start by tester |
|
TEONVST |
time used to indicate the pressure has stabilized at zero (EONV-diagn.) |
|
TEONVVACBP |
Time unsed to indicate the Phase 1 vacuum build (EONV-diagnostic) |
|
TEORA |
Detection time for ""ORA stable"" by exceed of diagnostic threshold |
|
TEPBKVMN |
Debouncing time for B_pbkvmn |
|
TEPBKVNB |
Time for steady state after braking |
|
TEPFGRH |
debounce time for CC lever signals |
|
TEPPBKV |
Debouncing time for switch pressure brake booster |
|
TEPUBLS |
Debouce time for brake light switch voltage not defined |
|
TERDASH |
time delay for dash detection |
|
TERMN |
Min. Engine run time to start EONV to be sure engine has warmed up |
|
TESAMN |
Min. time to activate adjustment of LSU in air after fuel-cutoff |
|
TESAMX |
Max. time for adjustment of LSU in air |
|
TETAMIMX |
filter time constant for computation of max. indicated torque |
|
TEVAPKOAU |
Antifreeze temperatur for A/C compressor switch off |
|
TEVFZCAN |
Delay time of vehicle speed error via CAN |
|
TFA1ELI |
Characteristic line to linearize the intake air temperature of tfa1 |
|
TFA1HSC |
high-side-check TFA1: temperature threshold for healing |
|
TFA1HSMLMX |
stuck-check TFA1: ml-threshold for high-phase |
|
TFA1HSMLO |
stuck-check TFA1: ml-threshold for low-phase |
|
TFA1HSMLU |
stuck-check TFA1: ml-threshold for low-phase |
|
TFA1HSTMMN |
stuck-check TFA1: tmot-threshold for high-phase |
|
TFA1HSVFMN |
stuck-check TFA1: vfzg-Schwelle for low-phase |
|
TFA1HSVFMX |
stuck-check TFA1: vfzg-Schwelle für high-phase |
|
TFA1RP |
Replacement value of the intake air temperature tfa1 |
|
TFA2ELI |
Characteristic line to linearize the intake air temperature of tfa2 (SY_TFAKON > |
|
TFA2PLMN |
plausibility-check of TFA2-sensor: lower-threshold for error detection |
|
TFA2PLMX |
plausibility-check of TFA2-sensor: upper-threshold for error-detection |
|
TFADTESKMX |
max. time after servie test request, DTEK has to be started |
|
TFANLCKU |
Time threshold: ""Fan lock up"" detection finished |
|
TFATLDMX |
max. duration for tank leak diagnosis systemtest at end of line |
|
TFAWUHOEN |
Maximum time for operation mode ""high overlap"" |
|
TFDMSHFM |
Time constant for filtering of HFM extreme value saving |
|
TFGRAQU |
tolerance time for aquaplaning detection during cruise control |
|
TFGRAR |
Ramp running time comfort shutdown of the FGR |
|
TFGRFDY |
Tolerance time for interventions by driving dynamics functions during FGR operat |
|
TFGRTP |
time for tip detection for cruise control buttons |
|
TFGRUEOB |
tolerance time for violation of upper acceleration threshold |
|
TFGRUM |
Tolerance time for detection of FGR-mode in function monitoring |
|
TFGRUNUB |
tolerance time for violation of lower acceleration threshold |
|
TFGRVRAB |
FGR: Time speed shutdown by vroh = 0 |
|
TFHKDDL |
time value to filter d/dt |
|
TFINJCTRST |
reset-time for fuil injected rolling counter (CAN) |
|
TFKAKORFV |
time for identification of mixture error suspicion |
|
TFKPVDS |
integrator speed for constant relative air charge adaption at boost control |
|
TFLQUALI |
time period for steady-state |
|
TFLTMOTMN |
temperature limit of tmot to influence of vfzg |
|
TFLTTMOT |
Delta engine coolant temperature above the environement temperature to allow th |
|
TFOAE |
debouncing time for oil level determination in freeway cycle |
|
TFOAM |
measurement time for oil level determination in freeway cycle |
|
TFOLE |
debouncing time for oil level determination in highway cycle |
|
TFOLM |
measurement time for oil level determination in highway cycle |
|
TFONL |
Required afterrun time for Oil-Level-Reset |
|
TFOSE |
debouncing time for oil level determination in city cycle |
|
TFOSM |
measurement time for oil level determination in city cycle |
|
TFPRDIFF |
Time constant filter of control deviation high-pressure control |
|
TFPRDR |
Time constant filter of rail pressure controller output |
|
TFRA |
monitoring duration FRA |
|
TFRAAKT |
Active time of FRA for reset of B_orastab |
|
TFRATHR |
time for setting the physical readiness at not activated lambda control |
|
TFRATZ |
dwell time for set of B_zfrat, if no error probability |
|
TFRECILAM |
time constant recilam filter |
|
TFRMST |
monitoring duration frm stabilized |
|
TFRMXNLH |
verification time for exceeding fr_w threshold to set homogeneous limp home mode |
|
TFRMXSCHDI |
verification time for exceeding fr_w threshold to disallow stratified mode |
|
TFRMZST |
duration of stay for unplausible frm-signal (short test) |
|
TFSRVSSTP |
max time of first Remote start engine run (backup) |
|
TFTEINI |
Time for detection of purge stop |
|
TFUELE |
fix substitude value at error model input value |
|
TFUELHPE |
fix substitude value at error model input value for tfuelhpsq |
|
TFUSFK |
Test time before setting non-plaus.-flag lambda sensor downstream front cat. |
|
TFWDKPN |
time constant for filtering DK angle before comp. with subs. value from charging |
|
TFWPFGR |
Time constant of the filter for calculation of wpfgr_w |
|
TGAALTWR |
time constant for reset of mixture correction on last trip value |
|
TGAFVINI |
time for the first mixture adaptation phase in case of error |
|
TGAGAE |
Duration for the first mixture adaptation phase, if cycle flage Z_ora is set |
|
TGAHR |
maximum time for homogenous request due to fault suspicion in mixture |
|
TGAINI |
Time for the first mixture adaptation phase without error |
|
TGANGAE |
Duration for the first mixture adaptation phase, if cycle flage Z_ora is not set |
|
TGAPA |
maximum Duration of mixture adaptation demand at low canister charge |
|
TGAPANS |
time after start for enabling of mixture adaptation demand |
|
TGENENPL |
|
|
TGFTDCVAL |
Debounce time for condition F terminal signal valid |
|
TGFTDEFFLT |
Debounce time for condition pwm signal default error |
|
TGFTMAXDEV |
Hold time for ftrmdc_w at quick change of duty cycle |
|
TGGLS |
Time needed for ADC after interrupt in the function calculator (Asic) |
|
TGSCHFGR |
Delaytime for freezing accelerator pedal after gearshift |
|
THDEVORMN |
minimum temperature for hpiv-o-rings while fault ""full delivery"" |
|
THDMB |
dwell time, healing for fault path for permanent torque limitation |
|
THDSTUS |
Time after end of engine start for mode change without acknowledge |
|
THDVABMN |
|
|
THDVABMX |
|
|
THDVGMX |
|
|
THDVMX |
|
|
THDVO |
|
|
THDVU |
|
|
THEALING |
waiting time for healing cycle |
|
THEH |
Time for maximal lambda sensor heating post cat after engine start |
|
THEXMX |
Max. admissible hexagon temperature at overrun adjustment |
|
THIGHVPC |
Time to check vehicle speed greater than VPOSTCRASH |
|
THLSUHR |
Verzögerungszeit zum Setzen der Bedingung B_henrin nach Einschalten der Heizung |
|
THLSUHRST |
Delay time to set condition B_henrin after start of heater, by start |
|
THMDMMA |
start temperature for thermostat temperature model |
|
THMDMME |
upper limit for thermostat temperature model |
|
THMDMMS |
temperature gradient of thermostat modelling during fuel cut-off |
|
THOLDPR |
Max time to hold the rail pressure. |
|
THOPP1 |
Fault time for high resistance test potentiometer 1 |
|
THOPP2 |
Fault time for high resistance test potentiometer 2 |
|
THP |
delay time failure heiling powerstage diagnosis |
|
THPVDSBAS |
Hold time for the preceeding desired boost pressure in case of large decrease of |
|
THSHA |
Delay time for sensor sufficiently heated |
|
THSPKHMN |
Minimum time after crank-up to enable homogeneous split-injection |
|
THSPKHMX |
Maximum time after crank-up while homogeneous split-injection enabled |
|
THSRIH |
Time del. readiness of Ri-measure. after switched on sensor heat. downstream cat |
|
THTABSTMN |
soak time threshold for enabling o2 purging after cranking |
|
THXDYNMX |
upper Temperature threshold for die dynamic diagnostic routine |
|
THYNWMN |
Temperature hysteresis for the avoidance of tmot and toelk fluctuations |
|
THYSEMOP |
Engine temperature hysteresis for activation / deactivation from EMOP |
|
TIGIFLAG |
time diagnosis current flag |
|
TIMINP |
minimum injection time |
|
TIMINP |
minimum injection time |
|
TIMINP_UM |
minimum injection time in function monitoring |
|
TIMLTM |
Delay time after exceeding the imlatm threshold |
|
TIO_UM |
Offset for rk-ti check |
|
TIPINOFSET |
delta torque for intitialize at dashpot |
|
TKANSWLMN |
Catalyst temperature threshold for start of O2 purging at post-start condintions |
|
TKAPDIADEL |
delay time of KAP-diagnosis |
|
TKATHKIMX |
upper catalyst temperature threshold for I-part lambda control downstream mainca |
|
TKATMLRHX |
upper catalyst temperature threshold for lambda control downstream cat |
|
TKATSZA |
Minimal catalyst temperature for forced a/f ratio modulation |
|
TKD |
Learning time for kick-Down position |
|
TKERDCMN |
|
|
TKERENSCUN |
Turn on threshold for diagnosis of UN of evaluation IC (based on temp.) |
|
TKERLSPSF |
Turn on threshold for pump current controller of evaluation IC (based on temp.) |
|
TKERLSUDMN |
minimum sensor temperature after time TVLSUBB |
|
TKERLSUMX |
|
|
TKERLSUS |
set temperature for ceramic of LSU |
|
TKERLSUST |
ceramic temperature threshold to stop start heating of LSU |
|
TKERLSVE |
Threshold to set immediately common sensor failure |
|
TKERRPSON |
Threshold to switch on reference pump current |
|
TKHFSAB |
delay time switching to idle speed at drive at catalyst heating |
|
TKHKIFA |
Lower temperture threshold to enable i-part in case of function request |
|
TKHKPFA |
Lower temperture threshold to enable p-part in case of function request |
|
TKHMX |
maximum time for active catalyst heating |
|
TKHMXEXT |
Extension of maximum time for active catalyst heating due to the softening of th |
|
TKHNAB |
time for reducing idle speed at end of catalyst heating |
|
TKHSWS |
Transient-time for heat-flux request: from idle to load request |
|
TKHSWSLL |
Transient-time for heat-flux request: from load to idle request |
|
TKIHKBTS |
Threshold catalyst temperature in maincatalyst for component protection |
|
TKIHKSAO |
upper limit catalyst temperature in main catalyst |
|
TKIVKBTS |
Threshold catalyst temperature in precatalyst for component protection |
|
TKIVKMZWMN |
temperature threshold for precatalyst or main catalyst which triggers engine-pro |
|
TKIVKSAO |
upper limit catalyst temperature in pre-catalyst while fuel cut off |
|
TKKTDMNO |
minimum catalyst temperature for catalyst diagnosis, lower range |
|
TKKTDMNT |
minimum catalyst temperature for catalyst diagnosis, functional test |
|
TKKTDMNU |
minimum catalyst temperature for catalyst diagnosis, upper range |
|
TKKTDMXO |
maximum catalyst temperature for catalyst diagnosis, lower range |
|
TKKTDMXT |
maximum catalyst temperature for catalyst diagnosis, functional test |
|
TKKTDMXU |
maximum catalyst temperature for catalyst diagnosis, upper range |
|
TKL15DEB |
debounce time for pin KL15 |
|
TKL15TALV |
delay of B_kl15 if empty tank is not validated |
|
TKOAMAD |
Inhibition time for AC compressor during adaptation of requirement |
|
TKOAMN |
minimum time for compressor off |
|
TKOAMNN |
minimum shutdown time for air-conditioning compressor |
|
TKOAMX |
maximum time for compressor off |
|
TKOBEMNN |
Minimum switch-on time for compres. after triggering by B_kobped or B_kobwped |
|
TKODPAMNN |
Minimum cut-out time of the air-conditioner compressors during acceleration (dwp |
|
TKODPAMXN |
Maximum cut-out time for compressor cut-out by dwped |
|
TKOFDEL |
delay time for turn on of air-conditioner compressor |
|
TKOFFSMN |
min. catalyst temperature to enable LSU offset determination |
|
TKOFFSMX |
max. catalyst temperature to enable LSU offset determination |
|
TKOGANGMN |
Min. compressor OFF time at gear shift |
|
TKOKO |
Monitoring time f. AirCon switch detection |
|
TKOMBKOA |
Engine temperature thresholt from panel board for switching the compressor off |
|
TKOMBKOE |
Engine temperature threshold from panel board for switching on the compressor |
|
TKOPEDCL |
Monitorin time f. compress. sw.off at DK closure |
|
TKOPEDCLMN |
Min. compressor OFF time at DK closure |
|
TKOSMX |
Min. delay time f. freezing of the compress. state |
|
TKOWPAMNN |
Minimum cut-out time at full load (by wped) |
|
TKOWPAMXN |
Maximum cut-out time at full load (by wped) |
|
TKRVFSN |
Delay-time during fast ignition advancing |
|
TKSCMHKMN |
Minimal catalyst temperature for update of ageing factor of the main catalyst |
|
TKSCMHKMX |
Maximal catalyst temperature for update of ageing factor of the main catalyst |
|
TKTDTO |
time out for enrichment, catalyst monitoring |
|
TKTDTOT |
time out for enrichment, catalyst monitoring for final test |
|
TLADEGFE |
Time limit: slow adjustment stable for DEGFE |
|
TLAFA |
delay time for activation of lambda demand by driver |
|
TLAKAMN |
min. duration condition lamsbrs_w or lamsons_w > 1.0 for cat. O2 neutralization |
|
TLASTEIG |
measuremet time of LSU signal gradient |
|
TLDIAN |
Delay time for updating i-adaption negativ |
|
TLDIAPN |
Delay time for updating i-adaption positiv |
|
TLDPTFFA |
fast filter time constant for low pass filtering of fuel tank pressure |
|
TLDPTFHP |
filter time constant for high pass filtering of fuel tank pressure |
|
TLDPTFNO |
filter time constant for noise reduction of fuel tank pressure signal |
|
TLDPTFSH |
filter constant for tank pressure high pass filtering for slosh detection |
|
TLDPTFSL |
slow filter time constant for low pass filtering of fuel tank pressure |
|
TLDRAEMN |
minimum threshold of time for calcultion of dldram_w |
|
TLDTVGW |
stop time neg. interv. duty cycle boost pressure control while expected gear sh. |
|
TLDUV |
time delay for closing the dump valve |
|
TLFFTDC |
|
|
TLFNS |
Amount of time to delay before removing the fan brake |
|
TLFRES |
time of delay prior to changing the fan speed (torque reseve) |
|
TLFSARMX |
maximum time for the after-run operation |
|
TLFSART |
time limit in after-run to compare engine coolant temperature |
|
TLFSL |
maximum time for the clutch slip condition |
|
TLFSLM |
length of time %Fan_Command for slip power management |
|
TLFSMN |
minimum time to remain in any fan speed (discrete fan system) |
|
TLFWPED |
maximum amount of time for the Wide open Throttle condition |
|
TLKD |
Maximum admissible time to learn the kick-down position via test driver |
|
TLLASH |
time delay for reset lamlash_w if lamsons_w is not lamlash_w |
|
TLRBAM |
blocking time for activation LC after acceleration enrichment |
|
TLRHS |
blocking time LC during hot start, triggered via thresholds TASHS and TMSHS |
|
TLRSZWSA |
Time for hard LC-switch on after fuel cut-off |
|
TLRTMS |
lock time for CL lambda control after start, depending on engine start temperatu |
|
TLRVAM |
blocking time for activation LC after deceleration enleanment |
|
TLSVEMN |
delay time for general electrical error of LSU (DLSVE) |
|
TMABDTAMN |
minimal threshold of engine-off temperature for plausibility check of TANS |
|
TMABDTMN |
minimal threshold of engine-off temperature for TMOT-diagnosis |
|
TMABSDSO |
temperature threshold tmotab to recognize cold soak |
|
TMADB0 |
Range 0 of engine temperature for STADAP calculation |
|
TMADB1 |
Range 1 of engine temperature for STADAP calculation |
|
TMADB2 |
Range 2 of engine temperature for STADAP calculation |
|
TMAKEMX |
max threshold of engine coolant temp for thermostat error by cooling down recogn |
|
TMAR |
Lower TMOT threshold for AR release |
|
TMASKIV1 |
temp. threshold for increasing 1st cat-interval, misfire detection |
|
TMASSTFUEL |
lowpass time constant mass_LT |
|
TMAXSAWE |
Maximum permissable time for cylinder individual fuel cut-off |
|
TMAXTH |
Theoretically achievable temperature by combustion without a performed torque |
|
TMBST |
duration for special torque limitation during and after start |
|
TMDCNWSMN |
Minimum ECT threshold for function request CAM phase (Device control) |
|
TMDCNWSMX |
Maximum ECT threshold for function request CAM phase (Device control) |
|
TMDHRSTMX |
minimum engine start temperature to perform start diagnosis |
|
TMDIFFN |
|
|
TMDIFFP |
|
|
TMDLLR |
Engine temperature threshold for ISC-actuator diagnosis |
|
TMDLLRKH |
Engine temperature threshold for engine speed diagnosis catalyst heating |
|
TMDMAD |
Engine temperature threshold to enable adaptation of resistant torque |
|
TMDMMA |
begin temperature for engine temperature model |
|
TMDMMAT |
Default temperature dependent on parking time during TDTMMA |
|
TMDMMAU |
lower start temperature from tans for engine temperature model |
|
TMDMMEE |
final temperature for substitute value of engine temperature |
|
TMDMMER |
final temperature for reference value of engine temperature |
|
TMDMN |
minimum engine temperature |
|
TMDMX |
maximum engine temperature |
|
TMDNWAMN |
Min engine temperature to enable diagnosis outlet camshaft control |
|
TMDNWAMX |
Max engine temperature to enable diagnosis outlet camshaft control |
|
TMDNWEMN |
Min engine temperature to enable diagnosis inlet camshaft control |
|
TMDNWEMX |
Max engine temperature to enable diagnosis inlet camshaft control |
|
TMDSTHDRO |
Upper threshold engine temperature for diagnosis start with high fuel pressure |
|
TMDSTHDRU |
Lower threshold engine temperature for diagnosis start with high fuel pressure |
|
TMDSUVR |
measurement time diagnosis dump valve |
|
TMDV |
motor temperature threshold for release of vehicle speed diagnosis |
|
TMDYNA |
engine temperature threshold to enable load dynamic adaptation |
|
TMEAKEMN |
minimum threshold of substitute engine temperature for cooling down recognition |
|
TMELIPU1 |
engine coolant temperature:calculation, inverse function 1 with activated pullup |
|
TMESSCMN |
minimum threshold of substitute engine temperature for stuck signal check |
|
TMFAWUHOMN |
Minimum engine temperature for operation mode high overlap |
|
TMFAWUHOMX |
Maximum engine temperature for operation mode high overlap |
|
TMFRATMN |
minimum temperature at it ftklra_w is one |
|
TMFRATMN |
minimum temperature at it ftklra_w is one |
|
TMFRATUB |
upper temperature threshold at it ftklra_w is constant |
|
TMFRST |
cut-in temperature for lambda closed-loop control short test |
|
TMFRSTEW |
subtitude value for cut-in temperature for mixture adaptation short test |
|
TMH |
engine-temperature - threshold warm |
|
TMHACOFFO |
tmot limit over which ""A/C off for Engine protection"" is set |
|
TMHACOFFU |
tmot limit over which ""A/C off for Engine protection"" is cleared |
|
TMHC2O |
tmot limit over which ""Engine Hot/Stop Engine"" is set |
|
TMHC2U |
tmot limit under which ""Engine Hot/Stop Engine"" is cleared |
|
TMHDVAB |
|
|
TMHLL |
tmot threshold for increased target speed at hot idling |
|
TMHSG |
engine temp. hot-start limit |
|
TMHSMAX |
Maximum value for ""high side check"" temperature model (tmhsrc) |
|
TMHSMIN |
Minimum value for ""high side check"" temperature model (tmhsrc) |
|
TMIBBR |
delay time for torque limitation with B_brems and wped>0 |
|
TMIBGREXS |
Max softening time period of the limiting torque in case of exclusive torque re |
|
TMILAS |
duration of activation of MIL after start for visuability test |
|
TMILRB |
duration of activation of MIL during ready blink |
|
TMILVT |
duration of activation of MIL after ini for visuability test |
|
TMISTMN_UC |
minimal engine temperature for actual torque calculation in IT |
|
TMISTMN_UM |
minimal engine temperature for actual torque calculation in Monitoring |
|
TMK |
engine-temperature - threshold cold |
|
TMKHTVK |
max. engine temperature for heat-request basing on modelled cat.-temperature |
|
TMKOAO |
Upper coolant temperature for switching off the AC-compressor |
|
TMKOAU |
Lower coolant temperature for switching off the AC-compressor |
|
TMKOSLUG |
maximum engine temperature for antislugging action |
|
TMKR |
engine-temperature threshold to enable knock control |
|
TMKRA |
engine temperature threshold for adaptive knock control |
|
TMLAST |
blocking time until the initialization of the AR is triggered at deceleration |
|
TMLAWLOFF |
temp. threshold to switch of calculation of desired afterstart lambda |
|
TMLFAFO |
engine cooling temperature above which After-run operation is started |
|
TMLFAFU |
engine cooling temperature above which After run operation is started |
|
TMLFARHIOF |
Curve: Engine temperature for fan after-run |
|
TMLFAROF |
Engine coolant temperature below which After run is termined |
|
TMLFHTO |
Engine coolant temperature threshold for the Hot Telltate Control |
|
TMLFHTU |
Engine coolant temperature threshold for the Hot Telltate Control |
|
TMLFKOO |
Engine temperature threshold to disengage the A/C clutch |
|
TMLFKOU |
Engine temperature threshold to reengage the A/C clutch |
|
TMLFS1O |
Upper engine temperature threshold for fan control, step 1 |
|
TMLFS1U |
Lower engine temperature threshold for fan control, step 1 |
|
TMLFS2O |
Upper engine temperature threshold for fan control, step 2 |
|
TMLFS2U |
Lower engine temperature threshold for fan control, step 2 |
|
TMLFS3O |
Upper engine temperature threshold for fan control, step 3 |
|
TMLFS3U |
Lower engine temperature threshold for fan control, step 3 |
|
TMLFSCO |
Upper engine temperature threshold for fan control, cold ambient |
|
TMLFSCU |
Lower engine temperature threshold for fan control, cold ambient |
|
TMLFSDCV |
Device control fan control: max. engine temperature |
|
TMLIM |
TMOT threshold for KSTAA active at after start |
|
TMLLX |
Threshold for boiling prevention |
|
TMLRTMS |
engine temp. threshold for lambda control depending on cranking temp. tmst |
|
TMLRZAMN |
Minimum engine coolant temperature for compulsory amplitude |
|
TMLUSTESTH |
Delay time to supress changes of air mass for sensor downstr. main cat |
|
TMMIBGR |
tmot threshold for enabling of torque limitation |
|
TMMKH |
Time after start for higher permitted torque during Kat-heating |
|
TMMKH_UC |
Time after start for higher permitted torque during Kat-heating in instruction t |
|
TMMKH_UM |
Time after start for higher permitted torque during Kat-heating |
|
TMMNEDTFA |
Minimum engine temperature to enable the electrical check of the intake air temp |
|
TMMNHSPKH |
Minimum engine temperature for request of hom.split injection for cat. heating |
|
TMMSADMN |
Min Engine Coolant Temperature For Mass Air Flow Adaptation Enable |
|
TMMSVZPAO |
Upper threshold of MSV two-point-control |
|
TMMSVZPAU |
Lower threshold of MSV two-point-control |
|
TMNDEN |
Temperature minimum for IUMPR-evaluation |
|
TMNDSTHDP |
Min. temperature for low pressure start with activated high pressure pump |
|
TMNHTOHTLD |
minimum time between two halts for new request of TLD |
|
TMNIDLEGD |
Minimum time length in idle f. calc. of General Denominator |
|
TMNIMPCYCL |
Time threshold for dcy-condition on gen. denom. |
|
TMNIMPIDLE |
Time threshold for idle-condition on gen. denom. |
|
TMNIMPVFZG |
Time threshold for vehicle speed condition on gen. denom. |
|
TMNKUPMN |
Temperature minimum for setting of B_kupplv |
|
TMNSADMN |
Minimal engine temperature for afterstart adaptation |
|
TMNSADMX |
Maximal engine temperature for afterstart adaptation |
|
TMNSMN |
engine temperature limit (for post-start torque increase) |
|
TMNSMN_UM |
Engine temp. threshold for the after-start expansion in the watchdog function |
|
TMNTRIPGD |
Minimum time length of driving cycle for calculation of General Denominator |
|
TMNVFZGD |
Minimum time length above vehicle speed limit f. calc. of General Denominator |
|
TMNWKH |
Temperature threshold f. release of NW-cat.heat. functionality |
|
TMNWLLKHA |
Engine temp. threshold for act. of cat. heating KF during idling outlet camshaft |
|
TMNWMN |
min engine temperature threshold to enable camshaft control |
|
TMNWMX |
max engine temperature threshold to enable camshaft control |
|
TMNWST |
threshold of engine temperature to enable camshaft control during start |
|
TMOD1PER |
periodic switching: time in mode 1 |
|
TMOD2PER |
periodic switching: time in mode 2 |
|
TMODNLF |
delay time for tyke back of limp home mode demand |
|
TMODT |
Threshold difference coolant temperature for hot start |
|
TMOHSHMN |
engine temperature enable sensor heating |
|
TMOMIN |
minimal engine temperature for hot engine |
|
TMOMIN_UC |
minimal plausible engine temperature in instruction test |
|
TMOMIN_UM |
minimal plausible engine temperature |
|
TMOTDEF |
Engine cooling temperature default value for the transmission temperature model |
|
TMOTDMD |
|
|
TMOTELI |
engine temperature calculation, inverse function |
|
TMOTFADK |
engine temperature for enable adaption of throttle blade |
|
TMOTFCNT |
Lowpass filter time constant for engine coolant temperature |
|
TMOTHKS |
min. engine coolant temperature for mode homogeneous knocking prevention |
|
TMOTHSH |
engine temperature for reduction lambda sensor heating |
|
TMOTHSP |
Min. engine coolant temperature for homogeneous split mode |
|
TMOTKASMN |
Minimal value of tmot for catalyst purge following engine start |
|
TMOTLFDK |
engine coolant temperature, below which reduction in %Fan_command is allowed |
|
TMOTLFN |
Engine temperature below which ajustments to Vehicle_%fan_required allowed are |
|
TMOTMRSMX |
Maximum engine start temperature to confirm CSD error in the next trip |
|
TMOTNLDG |
Temperature threshold for the limp home function of the crankshaft sensor |
|
TMOTNLHI |
Upper threshold: Engine temperature, high speed fan after-run |
|
TMOTNLLO |
Lower threshold: Engine temperature, high speed fan after-run |
|
TMOTNMX |
Engine temperature threshold for activation of increased engine speed limit |
|
TMOTPOEL |
Engine temperature for enable of oil pressure diagnosis |
|
TMOTPSSVMN |
engine temperature threshold at which manifold pressure sensor could be frozen |
|
TMOTPSSVMX |
engine temperature threshold for defrosted manifold pressure sensor |
|
TMOTSTOFF |
temperature threshold for switch off function %BDEMST |
|
TMOTTFMN |
temperature limit for coldstart condition |
|
TMOTWRMK |
engine temperature for warm engine |
|
TMPUPOFF |
lower threshold of engine coolant temp. for disabling pullup resistor |
|
TMPUPON |
upper threshold of engine coolant temp. for enabling pullup resistor |
|
TMRAA |
cut-in temperature adaptive precontrol for lambda closed-loop control |
|
TMRAA |
cut-in temperature adaptive precontrol for lambda closed-loop control |
|
TMRZHLL |
tmot threshold for resetting the time counter for hot idling |
|
TMSADEX |
Debounce Time For Clean Throttle Detection Based on Air Flow Error |
|
TMSADPSPV |
Debounce time for enabling adaptation after pressure ratio is less then max limi |
|
TMSAKEO |
upper threshold of engine coolant temp. for cooling down recognition |
|
TMSAKEU |
lower threshold of engine coolant temp. for cooling down recognition |
|
TMSCDU |
Threshold of motor temperature to determine the similar conditions window |
|
TMSDTAO |
upper threshold of engine coolant temp. f. plausibility check of intake air TANS |
|
TMSDTAU |
lower threshold of engine coolant temp. f. plausibility check of intake air TANS |
|
TMSDTHMU |
lower threshold of engine coolant temp. for thermostat monitoring |
|
TMSEONVMX |
max. engine-temperature threshold for EONV diagnosis |
|
TMSEONVTMX |
maximum engine temperature for EONV start by tester |
|
TMSFDTHMO |
upper threshold of engine coolant temp. to enable thermostat monitoring |
|
TMSFDTHMU |
lower threshold of engine coolant temp. to enable thermostat monitoring |
|
TMSH |
engine temp. threshold for recognition cold start for measur. sensor downstream |
|
TMSHA |
threshold for engine switch-off temp. for measur. cooling sensor downstream cat |
|
TMSHEARLCA |
Max. Engine Temperture for early calculation of injection |
|
TMSHS |
threshold engine temp.for triggering of TLRHS-blocking time LC during hot start |
|
TMSKS |
engine temperature threshold for detection fuel in oil |
|
TMSNOGA |
threshold tms for endless purge control, if mixture adaptation without error |
|
TMSRCERR |
debouncing time for irreversible ASR/MSR deactivation in case of message fault |
|
TMSRCNU |
Debounce time for detection of discrepant updating |
|
TMSSSCO |
upper threshold of engine coolant temp. for stuck signal check |
|
TMSSSCU |
lower threshold of engine coolant temp. for stuck signal check |
|
TMSTABO |
char. linie for count up of ABO-counter dependent on start temperature |
|
TMSTCOOLST |
Temperature offset for cold start |
|
TMSTDMD |
|
|
TMSTHDHSPO |
max. engine coolant start temperature for hsp mode at start |
|
TMSTHDHSPU |
min. engine coolant start temperature for hsp mode at start |
|
TMSTHDRO |
Upper threshold engine temperature for start with high fuel pressure |
|
TMSTHDRPRE |
Threshold engine temperature for high pressure start with pre-injection |
|
TMSTHDRU |
Lower threshold engine temperature for start with high fuel pressure |
|
TMSTLDHB05 |
Engine start temperature for direct disabling of tank leak diagnosis by high eva |
|
TMSTLDMN05 |
Minimum engine start temperature for enabling tank leak diagnosis 0.5mm test |
|
TMSTLDMX05 |
Maximum engine start temperature for enabling tank leak diagnosis 0.5mm test |
|
TMSTMAD |
Threshold for engine temperature at start for adaptation of requirement |
|
TMSTSDSO |
temperature threshold tmst to recognize cold soak |
|
TMSTTE |
|
|
TMSTTLS |
Start temperature threshold for activation of empty tank stop diagnosis |
|
TMSUTMUMA |
Lower Tmot threshold for temporary UMA adapation |
|
TMSVAPL |
application parameter MSV-temperature |
|
TMSVQUALI |
time period for steady-state, tmsvm |
|
TMSVRECUR |
Threshold for end of start counter for activation of Reduced Current Control |
|
TMSVRECURO |
Lower Threshold for engine temperature for activation of Reduced Current Control |
|
TMSVRECURU |
Upper Threshold for engine temperature for activation of Reduced Current Contro |
|
TMTADIFF |
temperature limit for auxiliary heating before start |
|
TMTE |
engine-temperature threshold for canister purge |
|
TMTKS |
temperature threshold for start of integrated air mass for detection fuel in oil |
|
TMVER |
Debounce time: ETC torque limitation is active for a longer time |
|
TMVPHMNA |
Lower eng. temp. f. preventing unlocking of the exhaust CmS during start |
|
TMVPHMNE |
Lower eng. temp. f. preventing unlocking of the intake CmS during start |
|
TMVPHMXA |
Upper eng. temp. f. preventing unlocking of the exhaust CmS during start |
|
TMVPHMXE |
Upper eng. temp. f. preventing unlocking of the intake CmS during start |
|
TMWAFMN |
minimum engine temperature for angle adaptation camshaft |
|
TMWUC |
engine temperture threshold for fulfilment ""warm up cycle"" |
|
TMWUC |
engine temperture threshold for fulfilment ""warm up cycle"" |
|
TMWUCST |
engine temperture threshold during cranking for fulfilment ""warm up cycle"" |
|
TMXEMOP |
Max. Temperature threshold for activating EMOP |
|
TMXTFA1STC |
stuck-check TFA1: tmst-threshold for enabling the diagnosis |
|
TMXVDNWVP |
Delay time after end of start to dissable diagnosis camshaft control DNWVPx |
|
TN2FGRGA |
double denominator time constant for cruise control |
|
TNACMX |
maximal time for Engine speed nac after S-ko = 0 |
|
TNALU |
duration of test-phase after detected misfire |
|
TNGAT |
Time constant for torque limitation by exhaust temperature |
|
TNLEKPVL |
threshold ECM-afterrun for EKP-lead time |
|
TNLETM |
increasing of switch-off delay time in case of E_tm |
|
TNLPHWAIT |
Time to expand the tooth period by B_rphsp |
|
TNLSGM |
Delay time for ECU shut-off |
|
TNLSGMN |
minimum time for ECM-switch-off delay |
|
TNLSGMNL |
minimum time for ECM-switch-off delay |
|
TNLSGMX |
maximum time for ECM-switch-off delay |
|
TNLSGMXL |
maximum time for ECM-switch-off delay |
|
TNLSYNMX |
Minimum time of the phase period to release the synchronisation |
|
TNMNPSR |
Time when ambient pressure in manifold |
|
TNMNSRMDK |
Time when ambient pressure in manifold |
|
TNMXH |
Maximum duration of increased engine speed limit |
|
TNODTES |
time after engine start prohibition of TE diagnosis |
|
TNOZWKH |
Time of disabling cat. heating after thermal protection / no spark retard |
|
TNSADHMX |
Maximal hold time for afterstart adaptation factor at high engine speed |
|
TNSADMX |
Maximal time for afterstart adaptation |
|
TNSC |
post-start monitoring time |
|
TNSEDSTD |
Time since start for healing for check of tank pressure sensor for drift |
|
TNSEFRAT |
time after start for the enabling of tempeature dependent adaptation |
|
TNSEMOP |
Min. time after start for enable EMOP |
|
TNSEPUSAFZ |
Time after end of start at which pu corresponds to pu at the start |
|
TNSEPUSAFZ |
Time after end of start at which pu corresponds to pu at the start |
|
TNSETLD05 |
time threshold after start end for enabling 0.5mm tank leak diagnosis |
|
TNSETLS |
time after start threshold for activation of empty canister stop diagnosis |
|
TNSEVPD |
Delay time for usage of ambient temperature for calculation of ration of evapora |
|
TNSKHTVK |
Time after crank-up, while heat-request bases on modelled cat.-temperature |
|
TNSNOGA |
threshold tns for endless purge control, if mixture adaption without error |
|
TNSNSWLAD |
time after start for after start and warm-up correction de-activation |
|
TNSOF |
debounce time for turning off the post-start torque increase |
|
TNSRT |
max. time after start to retrigger calculation of engine temperature model |
|
TNSRT |
max. time after start to retrigger calculation of engine temperature model |
|
TNSSTAEVAB |
Delay after automatic start before EV-shutdown by starter-relais-error |
|
TNSTBKV |
time after end of start, while pump mustn't be controlled activ |
|
TNSTDLLR |
Time delay until idle speed control diagnosis is activated |
|
TNSTDNH |
time after start for diagnosis wire-to-wire (monoflop) |
|
TNSTFON |
time after engine start to enable adaptation stop (healing) |
|
TNSTKASMX |
Maximal value of tnst_w for catalyst purge following engine start |
|
TNSTKOM |
Min. compressor OFF time after start |
|
TNSTMSAD |
Min Time After Engine Start For Mass Air Flow Adaptation Enable |
|
TNSTMSADEX |
Max Time After Engine Start for Clean Throttle Detection |
|
TNSTMSVZPA |
threshold time after start MSV two-point-control |
|
TNSTPRMX |
Time threshold for end of pressure limitation due to tightness o-rings connectio |
|
TNSTUSVB |
Time following start-up with switchover ban homogeneous - stratified |
|
TNSURLP |
Time rl prediction suppression in post-start |
|
TNSUUK |
disabling time of transient control during post-cranking |
|
TNSZVPHA |
Delay time after start end f. forced unlocking of the exhaust CmS |
|
TNSZVPHE |
Delay time after start end f. forced unlocking of the intake CmS |
|
TNWADAMX |
max. time for one edge adaption of camshaft phase sensor |
|
TNWADAMXA |
max. time for one edge adaption of camshaft phase sensor (fine tuning) |
|
TNWAPTA |
time outlet camshaft in active position by demand on tester |
|
TNWAPTE |
time inlet camshaft in active position by demand on tester |
|
TNWFARA |
time constant for ramp of desired angle at outlet camshaft by control of tester |
|
TNWFARE |
time constant for ramp of desired angle at inlet camshaft by control of tester |
|
TNWIFA |
time constant for filtered actual angle outlet camshaft |
|
TNWIFE |
time constant for filtered actual angle inlet camshaft |
|
TNWPPTA |
time outlet camshaft in passive position by demand on tester |
|
TNWPPTE |
time inlet camshaft in passive position by demand on tester |
|
TNWSBGLA |
Slow time const. f. des.val.change limit. exhaust cam. |
|
TNWSBGLE |
Slow time const. f. des.val.change limit. intake cam. |
|
TNWSPN |
Max Time after NWS direction change for Fuel Correction reset |
|
TNWSTPA |
max time position deviation intake camshaft until adjustment stop outlet active |
|
TNWSUK1 |
Debounce Time for Fuel Correction via Intake NWS |
|
TNWSUK2 |
Debounce Time for reset of Fuel Correction via Intake NWS |
|
TNWSUKR |
Delay for consecutive detecetion of NWS deviation |
|
TNWSWOT |
Fast time const. for des. valve change limit int. Cam during WOT launch |
|
TNWVBGNA |
delay time for beginning camshaft control of outlet camshaft by tester |
|
TNWVBGNE |
delay time for beginning camshaft control of inlet camshaft by tester |
|
TNWVIDIA |
Minimum time adjustment requirement outlet camshaft for IUMPR release denominato |
|
TNWVIDIE |
Minimum time adjustment requirement inlet camshaft for IUMPR release denominator |
|
TNWVPUA |
Time after which locking position of exhaust CmS is reliably left |
|
TNWVPUE |
Time after which locking position of intake CmS is reliably left |
|
TNWVPVA |
Control duration f. change in direction to unlock exhaust CmS |
|
TNWVPVE |
Control duration f. change in direction to. unlock intake CmS |
|
TNWWSPA |
Time spent in a position f. des. angle jumps exh. cam. |
|
TNWWSPE |
Rest time at one position at des. angle jumps (intake camshaft) |
|
TOBSUNW |
Hold time for B_sunw |
|
TOCVVACP |
Open time for canister vent after pressure build in Phase 2 |
|
TODCNWSMN |
Minimum engine oil temperature for function request CAM phase |
|
TODCNWSMX |
Maximum engine oil temperature for function request CAM phase |
|
TOELDNWAMN |
Min oil temperature to enable diagnosis outlet camshaft control |
|
TOELDNWAMX |
Max oil temperature to enable diagnosis outlet camshaft control |
|
TOELDNWEMN |
Min oil temperature to enable diagnosis inlet camshaft control |
|
TOELDNWEMX |
Max oil temperature to enable diagnosis inlet camshaft control |
|
TOELNWEMN |
Min. threshold of oil temperature to enable camshaft control (error of sensor) |
|
TOELNWEMX |
Max. threshold of oil temperature to enable camshaft control (error of sensor) |
|
TOELNWMN |
Min. threshold of oil temperature to enable camshaft control |
|
TOELNWMX |
Max. threshold of oil temperature to enable camshaft control |
|
TOEXTHK |
Temperature correction for main catalyst below light-off temperature |
|
TOEXTVK |
Temperature correction for precat below light-off temperature |
|
TOEXTVKG |
Temperature correction for washcoat only catalyst below light-off temperature |
|
TOFLRHOF |
Turn off delay für condition B_lr/B_lrhk, if these conditions are reset |
|
TOILSON |
debounce time oil switch signal |
|
TOLCHLLMN |
|
|
TOLCHLLMX |
|
|
TOLDMN |
Oil temperature min. |
|
TOLDMX |
Oil temperature max. |
|
TOLDSS |
Tollerance manifold pressure sensor to ambinent pressure during start |
|
TOLDSU |
Tolerance of the ambient pressure sensor in the start |
|
TOLDSVD |
Tolerance of the pressure sensor upstream of the throttle valve in the start at |
|
TOLE |
Replacement value for oil temperature |
|
TOLE |
Replacement value for oil temperature |
|
TOLELI |
(engine-) oil temperature calculation, inverse function |
|
TOLHL1 |
oil temp. threshold 1 for condition B_hll1 |
|
TOLHL2 |
oil temp. threshold 2 for condition B_hll2 |
|
TOLLFO |
Engine oil temperature threshold for the required fan power |
|
TOLLFU |
Minimum engine oil temperature threshold for the required fan power |
|
TOLRHINRL |
Turnoff delay time for disabeling of I part due to leaving the nmot-/rl-conditio |
|
TONFRLIM |
Debounce time condition controller saturation and signals pre/post cat differing |
|
TOPFRSTTON |
Turn on delay for enabling the transmission oil pump for the first drive cycle |
|
TOPNMOT |
Engine speed threshold to activate the transmission oil pump |
|
TOPONTIME |
Minimal activation time of the transmission oil pump |
|
TOPPWG0 |
Power threshold to activate the transmission oil pump in neutral or illegal gear |
|
TOPPWG1 |
Power threshold to activate the transmission oil pump in gear 1 |
|
TOPPWG2 |
Power threshold to activate the transmission oil pump in gear 2 |
|
TOPPWG3 |
Power threshold to activate the transmission oil pump in gear 3 |
|
TOPPWG4 |
Power threshold to activate the transmission oil pump in gear 4 |
|
TOPPWG5 |
Power threshold to activate the transmission oil pump in gear 5 |
|
TOPTMOT |
min. engine temperature to allow the device control: tranmission oil pump |
|
TOPTON |
Engine coolant temperature threshold for arming the transmission oil pump |
|
TOPVLPT |
Lowpass filter time for vehicle speed used in the transmission oil pump function |
|
TOPVON |
Vehicle speed threshold for arming the transmission oil pump |
|
TORA |
monitoring duration sufficient |
|
TORAAK |
activation duration ora without wating for fra |
|
TORAAKT |
Active time of ORA for reset of B_frastab |
|
TORNWMX |
threshold of oil temperature to enable adaption of camshaft |
|
TORNWTMX |
threshold of oil temperature to enable adaption of camshaft by demand on tester |
|
TOUTPWM |
|
|
TP157APERIOD |
|
|
TPACCSRYOF |
debounce time for switch off accessory |
|
TPAST |
debounce time starter activation |
|
TPDRLHK |
time constants of drlas filtering |
|
TPEDLA |
Time for keeping adapted idle end threshold active |
|
TPHRLSU |
Period for heater timing of LSU |
|
TPITOL |
Debouncing time for oil temperature signal plausibility error |
|
TPKL15M |
debounce time for pin KL15 depending on engine temperature |
|
TPLPU |
time constant for ambient pressure lowpass filter |
|
TPLRHLR |
Time constant of calculation the mean value of B_lr |
|
TPMMX |
Max. time to execute the pressure monitoring of the EONV Diag. |
|
TPMSHFMN |
period lower limit for detection short cut of HFM |
|
TPMSHFMX |
period upper limit for detection short cut of HFM |
|
TPNSE |
Test time after start end for DVE diagnostic routine |
|
TPNSE1 |
Test time after start end for PWG diagnostic routine |
|
TPREL |
tooth debouncing time during initialisation |
|
TPREL_MSV |
Tooth debouncing time during initialisation for enabling MSV |
|
TPRMINMSVMXL |
|
|
TPRMNMSVMX |
Max. time for extending holding phase of mass flow valve at low rail pressures |
|
TPSINIPL |
time for valid psini after engine start |
|
TPSRSVMN |
min time for defrost manifold sensor at min temp |
|
TPSRSVN |
Time for operating point of signal-variation-check |
|
TPTEE05 |
time for detection of stabilized tank pressure (0.5-mm-check) |
|
TPTEEBMX |
maximum waiting time for detection of stabilized tank pressure |
|
TPUCA_T_UM |
Interval of cyclical activation of the TPU test in the function monitoring |
|
TPUCR_T_UM |
Error time of TPU code ram test in the function monitoring |
|
TPULSIBH |
Time delay for currentpuls if sensorvoltage stay within band downstream cat |
|
TPURA_T_UM |
Interval of cyclical activation of the TPU code ram test in the function monitor |
|
TPURSTA_UM |
Maximum number of resets from the TPU monitoring |
|
TPUST_T_UM |
Delay time after synchro for activation of the TPU monitoring |
|
TPUTEDSV |
timer start value for change of ambient pressure |
|
TPU_T_UM |
Fault time for the TPU-monitoring in the function monitoring |
|
TPVDPLMN |
debounce time for detection of npl-error of PVD |
|
TPVDR |
delay time for error entry in E_psrr |
|
TPVDSLP |
Time constant for filtering desired boost pressure pvds_w |
|
TPVLLKHP |
Time constant high pass for pvllk_w filtering |
|
TPVLLKHPF |
Time constant high pass for pvllk_w filtering |
|
TPWGLRN |
Time constant to adapt pedal idle position |
|
TPWRSV |
Waiting time before DV-E Powersave becomes active |
|
TQTEAB |
time for decrementation of the purge rate |
|
TQTEXMAB |
time for decrementation of the spec. purge fuel amount |
|
TRAMPD |
Time until diabling the next cyl. during ramp down mode |
|
TRAMPU |
Time until enabling the next cyl. during ramp up mode |
|
TRANTHM |
Transsmision thermal mass |
|
TRAU |
monitoring time for lower load limit of lambda closed-loop control |
|
TRBGRK |
time delay after roll up for clutch torque limitation |
|
TRDYSHINI |
init value of transient time oxygen sensor downstream cat. |
|
TREHSH |
time for restart sensor heating or diagnosis of power stage |
|
TRFDYSHMX |
Thresholdfor transient time of oxygen sensor downstream main catalyst |
|
TRFDYSHMX |
Thresholdfor transient time of oxygen sensor downstream main catalyst |
|
TRFDYSHMX |
Thresholdfor transient time of oxygen sensor downstream main catalyst |
|
TRIAKTH |
Time needed for Ri-calculation up to date downstream catalyst |
|
TRIIMPH |
Time needed for pump impulse for both banks downstream catalyst |
|
TRINSTART |
|
|
TRIPFASH |
Short trip: minimum time for active close loop reguation pre catalyst |
|
TRLRLSDKMN |
min.time constant for time constant rl/rlsol-low-pass filter in the suction area |
|
TRMTSTREQ |
Delay before setting RVS request |
|
TRNX |
Debouncing time fault type max.: critical engine speed |
|
TRQPRSOL |
Timeout for Device control: Demand fuel high pressure |
|
TRQTBKVP |
Timeout for Device control: Brake boost vacuum pump |
|
TRQTMSV |
Timeout for Device control: MSV with engine speed |
|
TRSAFA |
monitoring time cabel brocken (downstream CAT) funct. requ. for Short trip |
|
TRSAH |
monitoring time cable brocken (Voltage within range) for sensor downstream cat |
|
TRSEH |
monitoring delay time for closed-loop control on for sensor downstream cat |
|
TRVSMONOFF |
switch-off de-bouncing for RVS monitoring |
|
TSABGE |
Temp. replacement value f. exhaust gas temperature sensor |
|
TSAKAMN |
minimum duration of fuel cut-off for catalyst oxygen neutralization |
|
TSALASH |
Time after fuel cut-off for the checking of the sensor downstream catalyst |
|
TSALSUMX |
max. time beween 2 adjustments of LSU in are due to up to date condition |
|
TSBINVALID |
Number of synchros with initialisation value tsroh_f |
|
TSBSEGINI |
initialisation value for segment duration related to 360 derees crankshaft |
|
TSCMEMXH |
Time window for OSC measurement main catalyst |
|
TSEGMIN_UM |
Min. segment time in the engine speed calc. with segment times in the FU |
|
TSGSCERR |
Debounce time for irreversible SGS shutoff on message error |
|
TSGSCNU |
Debounce time for considering grid offset on message counter |
|
TSHFTACT |
Delay time of Gear shift detection |
|
TSHFTACTMX |
maximum time limit of Gear shifting |
|
TSOBGMSAD |
Time after switch off to start interpolation |
|
TSPRMX |
temperature threshold for pressure limitation due to tightness o-rings connectio |
|
TSPRMXO |
Temperature threshold for end of pressure limitation due to tightness o-rings co |
|
TSRCDV |
Timer to detect signal range check at vehicle speed diagnosis |
|
TSRFDKI |
fixed time for initialization (throttle self-cleaning-function) |
|
TSRFDKO |
fixed time for upper stop position (throttle self-cleaning-function) |
|
TSRFDKU |
fixed time for lower stop position (throttle self-cleaning-function) |
|
TSSRVSSTP |
max time of second Remote start engine run (backup) |
|
TSTA |
delay time to detection blocking engine |
|
TSTA |
delay time to detection blocking engine |
|
TSTABTI |
|
|
TSTALOWVMX |
max. time starter-driving during 5V-undervoltage |
|
TSTAPLMDS |
delay after cranking for enable adaptation pslm-pdss |
|
TSTAPVL |
Time for activation of EKP by automatic start |
|
TSTARES |
max. dead time for CAN signals after an ECU reset |
|
TSTARTERMN |
Starter minimal running time. |
|
TSTARTERMX |
Starter maximal running time. |
|
TSTASL |
Delay timer for B_st during anti-slug |
|
TSTEKPV |
delay time for automatic start (fuel pump) |
|
TSTENDDSNO |
threshold to avoid fault diagnosis, failure EKP or empty fuel tank |
|
TSTPTLD |
Delay time for decision Tank Leakage Diagnosis can not run |
|
TSUVAMN |
Minimum time, for which dump valve is controlled for opening |
|
TSUVAMNAC |
Minimum time, for which dump valve is controlled for opening, for calculating ac |
|
TTANWLIA |
time constant slow I-part of camshaft controller(exhaust) |
|
TTANWLIE |
time constant slow I-part of camshaft controller(intake) |
|
TTANWRMAXA |
Time constant for output max. duty cycle camshaft controller (outlet) |
|
TTANWRMAXE |
Time constant for output max. duty cycle camshaft controller (inlet) |
|
TTBMH |
period for theoretical operation readiness of sensor with heating |
|
TTBRL |
Time between braking and setting B_brems=true (leakage) |
|
TTCW1 |
trigger-point T1a |
|
TTDELRDE |
minimum difference between old and new toothtime |
|
TTDSTDST |
Delay time for enable conditions of check of tank pressure sensor for drift |
|
TTDSTP |
time period for stabilization of low pass |
|
TTDSTPS |
|
|
TTEATMTPA |
|
|
TTEAUS |
Delay time after engine start for activating the purge control valve |
|
TTEDFTE05 |
canister load is lower a threshold for this time (0.5mm) |
|
TTEDFTEO05 |
high canister load is lower a threshold for this time (0.5mm) |
|
TTEDGK05 |
time for measurement of compensation gradient (0.5-mm-check) |
|
TTEDOZ |
minimum test time for rationality check of pressure sensor |
|
TTEDOZG |
overall test time for rationality check of pressure sensor |
|
TTEDOZG |
overall test time for rationality check of pressure sensor |
|
TTEDWD05 |
waiting time before measurement of vacuum decay gradient (0.5-mm-Prüfung) |
|
TTEDWU |
waiting time if pressure sensor at lower limit |
|
TTEFVINI |
first phase without range dependent adaptation in case of error(if nec. PC-Phase |
|
TTEGAE |
Phases without mixture adaptation (Z_ora = True, if nec. CPC-Phase) |
|
TTEMIN |
minimum time in which mixture adaptation no active (error case, maybe CPC-Phase) |
|
TTENCT05 |
delay time for display the purge period (0.5mm check) |
|
TTENGAE |
Phases without mixture adaptation (Z_ora = False, if nec. CPC-Phase) |
|
TTENOT05 |
max. time since last purge period (0.5mm check) |
|
TTEOFINI |
first phase without range dependent adaptation (flawless system) |
|
TTFLPR |
time constant lowpass tfuel temperature, tfuelhpm |
|
TTFTEADPTF |
time constant for filtering of the canister load factor |
|
TTIPINEN |
Time delay for consideration of torque transmission after nmot-dynamics |
|
TTIPINON |
On-Time for tip-in offset on max. spark retard |
|
TTLASH |
Time for voltage of O2 sensor post cat lower/higher than desired threshold |
|
TTLBUEDL |
Delay of trigger signal after recognizing idle phase |
|
TTLBUENO |
for TTLBUENO after idle trigger the trigger is not repeated |
|
TTLDVNL |
ECU switch off delay after end of tank leak diagnosis |
|
TTLDVNLST |
ECU switch off delay after end of tank leak diagnosis in case of service bay tes |
|
TTMOTTFUEL |
time constant for lowpass filter |
|
TTMSTIRMN |
Threshold: minimum ambient temperature for denominator increase |
|
TTMSTIRMX |
Threshold: maximum ambient temperature for denominator increase |
|
TTMT |
time constant lowpass motor temperature, tmsvm |
|
TTMUMASTA |
Time for steady-state during temp. UMA adaptation |
|
TTNSETEIR |
Threshold for accumulated engine on time to increase denominator |
|
TTOCC |
Threshold for detection timeout of CC message |
|
TTOLCORAB |
Time Threshold for switching of MAX choice for model of oiltemperature |
|
TTOPMKIST |
filtertime for actual torque in ATOP |
|
TTOPOFF |
off time for transmission oil pump |
|
TTOPON1 |
turn-on transmission oil pump, at first turn-on |
|
TTOPON2 |
turn-on transmission oil pump, from 2nd turn-on |
|
TTOPTUMN |
minimal ambient temperature for activation of TOP |
|
TTOPVWUMN |
minimal vehicle speed for start of warm-up timer |
|
TTPUBSYVFZ |
Debounce time for the TPU state ""BUSY"" to show the old measured period |
|
TTPUMESVFZ |
Debounce time for the TPU state ""IN MESUREMENT"" to show the old measured period |
|
TTRPROTOFF |
Transmission oil temperature threshold to exit the transmission overheat protect |
|
TTRPROTON |
Transmission oil temperature threshold to enter the transmission overheat protec |
|
TTUMGDSTD |
Temperature difference for cold start detection for check of tank pressure senso |
|
TTUMGIRMN |
Threshold: Minimum ambient temperature for denominator increase |
|
TTUMGIRMX |
Threshold: Maximum ambient temperature for denominator increase |
|
TUBCRTMN |
Time ubatt is lower as a threshold to switch to MIN crank time |
|
TUBNLMN |
Delay time afterrun switch-off after voltage drop below UBNLMN |
|
TUGDTX |
Time delay of the ugd condition calculated with the tolerance-bound throttle val |
|
TUHKLEANRP |
delay time for valid measurement of dynamic diagnosis downstream cat. |
|
TULV1 |
delay overcharge cutoff, ti fade out step 1 |
|
TULV3 |
Delay time for reset overload error |
|
TUMCLFO |
Upper ambient temperature for disabling cold algorithm fan control |
|
TUMCLFU |
Lower ambient temperature for disabling cold algorithm fan control |
|
TUMDETM |
substitute value of ambient (-air) temperature for engine coolant temp. model |
|
TUMDSTDMN |
Minimum ambient temperature for check of tank pressure sensor for drift |
|
TUMDSTDMX |
Maximum ambient temperature for check of tank pressure sensor for drift |
|
TUMDSTU |
Minimum ambient temperature for diagnosis of tank pressure sensor. |
|
TUMGDEF |
Environement temperature default value for the transmission temperature model. |
|
TUMGKTDMN |
minimum ambient temperature for catalyst diagnosis |
|
TUMGMNKH |
minimum ambient temperature for release of catalyst heating |
|
TUMTAI |
initial value of ambient temperature |
|
TUMTHEB |
Ambient temperature limit for tank leak diagnosis |
|
TUMTLDO |
upper TUMG-threshold for evap system monitoring |
|
TUMTLDU |
lower TUMG-threshold for evap system monitoring |
|
TUMTO |
Dead time for switch-over: CJ120 |
|
TUMTOE |
Dead time for switch-over: CJ120/CJ125 for electrical adjustment |
|
TUMTOE |
Dead time for switch-over: CJ120/CJ125 for electrical adjustment |
|
TUPWG12 |
Fault time during comparison of PWG potentiometer 1 and 2 |
|
TUPWG1O |
Fault time for upper violation of range by PWG potentiometer 1 |
|
TUPWG1U |
Fault time for lower violation of range by PWG potentiometer 1 |
|
TUPWG2O |
Fault time for upper violation of range by PWG potentiometer 2 |
|
TUPWG2U |
Fault time for lower violation of range by PWG potentiometer 2 |
|
TUSBELH |
Time for holding of the sensor voltage after on-load impulse downstream catalyst |
|
TUSBELH |
Time for holding of the sensor voltage after on-load impulse downstream catalyst |
|
TUSCHERKAH |
Time duration for the extension of condition successful overrun downstream mean |
|
TUSCHFMRH |
Delay time for the reset condition for across the sensorvoltage at overrun downs |
|
TUSCHUB |
Delay time for interference peaks at thrust detection of the rear oxygen sensor |
|
TUSDUFA |
time delay for detec. interc. short circuit sens. downstr.(func. rec.short-trip) |
|
TUSDUH |
time delay for detection intercore short circuit l. sensor downstr. cat. |
|
TUSEHKH |
Delay time after dew point end to enable check of heater downstr. cat |
|
TUSENLASH |
time for duration until lean/rich detection is downstream cat |
|
TUSHKRFM |
Time duration for release of oscillation check. (Reset F/M-Flip-Flop) |
|
TUSHZFH |
Time window to measure heater coupling to sensor signal downstr. catalyst |
|
TUSKS |
Time of inter. suppress. f. switching off single funct.:sensor downstr. the cat. |
|
TUSLASH |
Test time for duration enrichment/enleanment downstream catalyst |
|
TUSLASH |
Test time for duration enrichment/enleanment downstream catalyst |
|
TUSMAX |
monitoring time for Usmax |
|
TUSMCDYSH |
delay time for monotony check of dynamic diagnosis downstream cat. |
|
TUSRIBERH |
delay time for Ri- measurement after leaving the voltage range downstr. cat |
|
TUSSA |
delay time after crossing the control threshold downstream cat |
|
TUSTAL |
Delay for detection'wire to wire connection' after 'empty fuel tank for O2 po.ct |
|
TUSTALLASH |
Delay for detection B_maxlash after empty fuel tank for O2 po.ct |
|
TUSTALLASH |
Delay for detection B_maxlash after empty fuel tank for O2 po.ct |
|
TVAAV05 |
delay time before closing of canister vent valve (0.5-mm-check) |
|
TVABGL |
delay time for LSU adjusting |
|
TVANWSTEND |
Adjustable delay time after which start end has been reached |
|
TVARS |
delay time until antisurge is inactive again |
|
TVARSA |
Time f. activation of dynamic surge damp. interv. after fuel cut-off |
|
TVARSS |
delay time for AR active again in case of steady-state |
|
TVAST |
turn on delay time for request of sensor signal trimming |
|
TVBKVNHOM |
delay time for demand emergency operation HOM, because ps>psmxbkvg |
|
TVBRMX |
delay time for activation of board-function |
|
TVBSNPB |
|
|
TVBSNPV |
|
|
TVCLTODC |
L-terminal off timer expired |
|
TVDESHLSU |
Duty cycle after end of start ramp to activate diagnosis at sensor lines VM/UN |
|
TVDFRZAIP |
Settle time with dfrza > DFRZASNAMN |
|
TVDGENEST |
Delay after end of start for alternator power stage diagnosis |
|
TVDK |
delay time after closing of the throttle |
|
TVDKPRMX |
Max. delay time of DK prediction |
|
TVDNOZW |
time for delta engine speed without ignition angle intervention |
|
TVDOCVM |
Delay time to enable diagnosis ""open circuit at VM"" |
|
TVDRL |
Delay time for dynamics measurement LSU |
|
TVDSKVH |
Time constant for healing of pressure sensor error |
|
TVDSKVRH |
Time constant for healing of pressure sensor error |
|
TVENMX |
Delay of the diagnosis \max. pulse-duty ratio\ after heater on\ or after B_SA |
|
TVERBL |
delay time for brake-light-switch signal check |
|
TVERBR |
Delay time for brake-switch plausibility check |
|
TVEVLOCTE |
delay time for injection restart after suppression |
|
TVFAHRLSU |
Delay time due to function request |
|
TVFGKHTUM |
time delay of condition B_stend for evaluation of ambient temperature (catalyst |
|
TVFHSH |
Debounce time for rear Lambda sensor heater diagnosis |
|
TVFKOTH |
|
|
TVFKOTT |
time threshold for setting F-terminal fault at 'key-on test' |
|
TVFRSTSI |
time for the setting of bit missing signal |
|
TVFRTH |
|
|
TVFRTT |
time threshold for setting F-terminal fault at 'run test' |
|
TVFSAM2 |
Delay time after DRIVE-position switch off |
|
TVFSAWE |
Time delay until resetting of B_fil |
|
TVFSEM2 |
delay time after DRIVE-position switch on |
|
TVFSRAM2 |
Engine-temp.-dependent delay time for gear selection off (R) |
|
TVFSREM2 |
Engine-temp.-dependent delay time for gear selection on (R) |
|
TVFSTD |
delay time fuel level sensor diagnostic |
|
TVFSTDSOK |
delay time for Fuel-level electrical-check OK detection |
|
TVFVPVA |
Delay time f. enabling of unlocking the exhaust CmS |
|
TVFVPVE |
Delay time f. enabling of unlocking the intake CmS |
|
TVFZEHEAL |
Delay time for healing of the electrical error path DFP_FVZE |
|
TVFZGSUS |
Time to detect suspendig vehicle speed sensor |
|
TVFZGTFUEL |
lowpass time constant vfzg_LT |
|
TVGAIN |
delay time for change gain from 8 to 17 |
|
TVGAT |
Delay time for torque limitation by exhaust temperature |
|
TVGATUP |
Turn on delay time for torque limitation by exhaust temperature |
|
TVGSCH |
Delay time for condition: gear shift active |
|
TVHATAIR |
|
|
TVHSHEE |
Debounce time for heater output stage diagnosis downstream kat |
|
TVHSHRI |
Delay time for Ri fault downstream kat |
|
TVHSHRIHEL |
Delay time for healing Ri fault downstream kat, if B_npfhsh =1 |
|
TVHSHRIZ |
Delay time for healing Ri fault downstream kat |
|
TVKOED |
switch-on delay at A/C turning-on |
|
TVKOEMXD |
Max. compress. ON time via tester after demanded sw.off |
|
TVKOLS |
Delay time f. compress. sw.off at low engine speeds |
|
TVKOM |
Delay between B_kom and B_koe |
|
TVKOMOF |
delay time for compressor off |
|
TVKONOFF |
t ime |
|
TVKORES |
Delay time for built-up of torque reserve |
|
TVKOSLUG |
maximum amount of time for antislugging action |
|
TVKTDB |
time delay Start catalyst diagnosis |
|
TVKTDLE |
cat monitoring: delay time until lambda stabilized |
|
TVKTDLL |
time delay after idle for start catalyst diagnosis |
|
TVKTDMLS |
time delay enable catalyst diagnosis after air mass steady |
|
TVKTDMTPE |
time delay enable catalyst diagnosis after dew point end, in dependant of engine |
|
TVKTDRMX |
maximum richt time for rear sensor at cat. monitoring |
|
TVKTDTKB |
time delay dependant of temperature for enable catalyst monitoring |
|
TVKTDTKS |
time delay enable catalyst diagnosis after catalyst temperature steady |
|
TVKUP |
Delay time for B_kupplv |
|
TVKUPARE |
delay tine of unclutching for anti-jerking function |
|
TVKUPGW |
Delay time prior to reset of B_kupgw after engaging |
|
TVKUPHS |
delay time for clutch switch during shifting in higher gear |
|
TVKUPPL |
Delay time for the cluch information |
|
TVKUPRS |
delay time for clutch switch during shifting in lower gear |
|
TVKUPV |
delay time for resetting of B_kupplv |
|
TVKUPVN |
Additional delay time for resetting of B_kupplv |
|
TVKUPVX |
delay time for resetting of RS-FF for setting of B_kupplv |
|
TVLADV |
Integrator time constant at vlast-calculation |
|
TVLBTSNVK |
Delay time for lambda request for component protection due to temperatures downs |
|
TVLDMN |
minimum limit, on/off ratio for boost control |
|
TVLDMX |
limit, on/off ratio (max.) for boost control |
|
TVLDMX |
limit, on/off ratio (max.) for boost control |
|
TVLISTU |
Time during witch a negative integrator value is forbidden |
|
TVLKOTT |
time threshold for setting L-terminal fault at 'key-on test' |
|
TVLLR |
turn-on delay: B_llri at engine speed overshoot |
|
TVLLRI |
delay time to enable I-component after start-up |
|
TVLLRPD |
Maximal delay time to enable PD components after start-up |
|
TVLLRPST |
delay to disable proportional parameter in start |
|
TVLLRST |
delay to disable proportional parameter in start |
|
TVLLRSTE |
enable idle speed control after start |
|
TVLLRSTE |
enable idle speed control after start |
|
TVLRA |
delay time for activation of the lambda adaption after lambda control active |
|
TVLRHLR |
Delay time wenn B_lr ist disable |
|
TVLRTT |
time threshold for setting L-terminal fault at 'run test' |
|
TVLSUBB |
Maximum permitted delay time after start for operating readiness of LSU |
|
TVLSUDIP |
Delay time to set condition: ""sensor signal near 1.5V"" (B_lsudip) |
|
TVLSULUFT |
Delay time for fault LSU in air |
|
TVLSUTRIM |
Delay time for fault LSU interrupt trim resistor |
|
TVLSUTRIMF |
Delay time for fault LSU interrupt trim resistor on FA |
|
TVLSUTRIMZ |
Delay time for healing/cycle flag interrupted IA line |
|
TVLSUTRZF |
Delay time for healing/cycle flag interrupted IA line, (B_Fa) |
|
TVLSUUMN |
Delaytime Detection of Voltage fault during fuel-cut-off |
|
TVLTKOH |
|
|
TVLTRTH |
|
|
TVMDTRAEGM |
delay after start for computation of synamic torque |
|
TVMIBEG |
debounce time for activation of ignition intervention during torque limitation |
|
TVMINMKU |
Max duration of gear shift for not limiting engine speed via air path |
|
TVMNDK |
Max duration for not limiting engine speed via air path |
|
TVMXLTOF |
cumulativ L-terminal off time |
|
TVMXPRG |
Speed prediction time for VMAX control |
|
TVNEVA |
Waiting period until next unlocking cycle of exhaust CmS |
|
TVNEVE |
Waiting period until next unlocking cycle of intake CmS |
|
TVNLGA |
Switch-off time for operating readiness for adaption factor |
|
TVNSADLROF |
Time delay switch off afterstart adaptation by active lambda control |
|
TVNSZWMS |
time delay after start for activation of ignition-angle for engine protection |
|
TVNWGE |
Delay time until switchover enable following transmission intervention |
|
TVNWPCA |
Time delay during which the normal duty cycle is applied for the Pin Cycler Algo |
|
TVNWPCE |
Time delay during which the normal duty cycle is applied for the Pin Cycler Algo |
|
TVNWSTTM |
delay time : enable of camshaft control after start, depending on engine temp |
|
TVNW_S |
Delay time after the inlet valve is in retarded position with certainty |
|
TVOCIPLL |
Delay time to set error open circuit at IP (frm) |
|
TVOCVM |
Delay time to set error open circuit at sensor line VM |
|
TVOFFSLR |
|
|
TVOSTANA |
debounce time before 'Standabkopplung' |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVP |
delay time failure verification powerstage diagnosis ME(D) 9 |
|
TVPBKVK |
time delay pressure of break booster constant |
|
TVPBKVNB |
Delay time of braking reaction after braking |
|
TVPDKP1 |
delay time for recognition of implausible signal from throttle potentiometer 1 |
|
TVPDKP2 |
delay time for recognition of implausible signal from throttle potentiometer 2 |
|
TVPHFS |
Debouncing time for fault of main charge sensor in GGDVE |
|
TVPKH |
delay: proportional parameter for kathalyst-heating |
|
TVPLANTF |
|
|
TVPLANTF2 |
|
|
TVPRMNPL |
Debouncing time of high pressure sensor range check |
|
TVPWDK12 |
Fault-tolerance time for checking synchronouso operation of DK potentiometers |
|
TVPWDK13 |
fault-tol. time checking sync.-operation pot. 1 and subs. value from charging |
|
TVPWDK23 |
fault-tol. time checking sync. operation DK-pot. 2 and subs. value from charging |
|
TVPYGAR |
dealy time for next homogenous request from mixture adaptation |
|
TVREABO |
delay time for reset of counter for fuel in oil |
|
TVRESLL |
Hold time for increased torque reserve after engine speed drop |
|
TVRESTM |
Initialization period: torque reserve after start-up |
|
TVRIHEE |
Delay time for Ri fault |
|
TVRIHOCVM |
|
|
TVRINNPH |
Delay time to stop 3kHz modulation because Ri is too high |
|
TVRPSONMX |
|
|
TVRSTHDEBF |
Max. waiting time for high fuel pressure at initial fueling mode |
|
TVSABFA |
SA-delay time at function request ((B_fa) and gangi = 0 |
|
TVSABGL |
delay time for LSU adjusting after starting |
|
TVSABTE |
delay time for CPV colsing vor fuel cut off |
|
TVSADYN |
Delay time for condition B_sadyn |
|
TVSAG0 |
delay fuel cut off at gear 0 |
|
TVSALSUMN |
minimum active fuel cut off time to evaluate statistic block |
|
TVSAOCVM |
Delay time after fuel cut off to activate Diagnosis on open circuit at line VM |
|
TVSATMOT |
Turn-on delay to activate adjustment of LSU in air due to motor temperature |
|
TVSATMOTFA |
FR Turn-on delay to activate adjustment of LSU in air due to motor temperature |
|
TVSAUGST |
turn on delay time for start of sensor signal trimming |
|
TVSDENO |
Delay of B_lrs at switch to homogeneous operation mode during regeneration |
|
TVSERSL |
delay time for setting error flag of monitoring of lambda sensor wires |
|
TVSERSL |
delay time for setting error flag of monitoring of lambda sensor wires |
|
TVSHEIP |
Delay time to set cycle flag Z_lsuip |
|
TVSHESL |
delay time for healing of lambda sensor wires faults |
|
TVSLRS |
Delay of B_lrs at negative edge of B_schicht |
|
TVSNPFNA |
Delay time to suppress disturbances at debounce time |
|
TVSTAEVAB |
Debounce time before switching off injectors after error at starter relay |
|
TVSTANDA |
debounce time after 'Standabkopplung' |
|
TVSTEND |
Time delay for B_stend |
|
TVSUDC |
VIM control duty cycle request flap on by device control |
|
TVTANKL |
Delay time for information canister empty-state terminated |
|
TVTEB |
delay time for locking of Purge control after switch off of Injection |
|
TVTIPLL |
wate time for tip-in active |
|
TVTKLSU |
Delay time for setting Error as a reason of empty tank |
|
TVTKLSU |
Delay time for setting Error as a reason of empty tank |
|
TVTLEPL |
delay time for enabling of empty fuel tank diagnosis |
|
TVTSO_UM |
Negative offset of KLTVTS_UM |
|
TVTUMTA |
delay for threshold velocity for determination ambient temperature |
|
TVUBFRA |
delay time for mixture adaptation demand FRA-range |
|
TVUBLRA |
switch off time for avoidance of opearating mode switchting in range limit |
|
TVUBORA |
delay time for mixture adaptation demand ORA-range |
|
TVUPRMNPL |
Time delay until setting of B_uprmnpl |
|
TVVALDYNSA |
Delay of B_valdyn |
|
TVZHRNOT |
maximal zul. Zeit für Unterbrechung der Startdiagnose |
|
TVZMSVRC |
Pullin Impulse for reduced Current control |
|
TVZWMSA |
Time until transition to continuously retarded limiting |
|
TVZWMSE |
Time until transition to dynamic retarded limiting |
|
TWADTHMS |
eng. start temp. depend. time for freezing temp. model of thermostat monitoring |
|
TWAFMN |
Lower threshold of the temperature field for fine adaption |
|
TWAFMX |
Upper threshold of the temperature field for fine adaption |
|
TWAKEOF |
accumulated waiting time out of matched area to reset cooling down recognition |
|
TWAKEON |
waiting time within matched area to set condition for cooling down recognition |
|
TWANLFO |
Transmission oil temperature threshold for the fan power |
|
TWANLFU |
Transmission oil temperature threshold for the fan power |
|
TWARMUPTOP |
warm-up time for daily cycle check TOP |
|
TWATMN |
minimum engine temperature for angle adaptation camshaft by demand on tester |
|
TWATMX |
maximum engine temperature for angle adaptation camshaft by demand on tester |
|
TWBDCY |
waiting time for condition 'driving cycle' |
|
TWBKLHOF |
accumulated waiting time out of matched area to reset cond. radiation power high |
|
TWBKLHON |
waiting time within matched area to set condition radiation power high |
|
TWBKLNOF |
accumulated waiting time out of matched area to reset cond. radiation power low |
|
TWBKLNON |
waiting time within matched area to set condition radiation power low |
|
TWDKNL |
time after nmot = 0 and Kl.15 OFF until run after |
|
TWDKRED |
Weighting time constant for filtering of reference throttle blade position |
|
TWDKSEB1 |
Time Setpoint 1 for DV-E ice breaking active |
|
TWDKSEB2 |
Time Setpoint 2 for DV-E ice breaking active |
|
TWDKSNST |
time constant for filtering of reference throttle blade position |
|
TWDMAD |
Waiting time to enable adaptation of resistant torque |
|
TWDTESKF |
wating time from finish DTESK until start EONV |
|
TWEONVNL |
key off waiting time until start of tank leak diagnosis EONV |
|
TWFSOLMN |
debounce time of condition oil level low |
|
TWFSOLOK |
debounce time of condition oil level o.K. |
|
TWHRLSUZFA |
|
|
TWHRLSUZMX |
|
|
TWHRSTMX |
maximum pipe wall temperature to set internal cycle flag of start diagnosis |
|
TWKFGR |
Delaytime for freezing accelerator pedal after opening converter clutch |
|
TWLRTMS |
waiting time up to check engine temp. signal exceeding threshold for closed loop |
|
TWNWSSRFA |
Time constant for lowpass filter setpoint camshaft outlet early |
|
TWNWSSRFE |
Time constant for lowpass filter setpoint camshaft inlet early |
|
TWNWSSRSA |
Time constant for lowpass filter setpoint camshaft outlet retarded |
|
TWNWSSRSE |
Time constant for lowpass filter setpoint camshaft inlet retarded |
|
TWPLK |
debouncing time for withdrawal of the idle input at life detection |
|
TWPMBBR |
Delay time for limiting pedal travel for operated brake |
|
TWRVSDKMX |
delay time for time RVS monitoring of max throttle position |
|
TWRVSNMX1 |
delay time for time RVS monitoring of max limit 1 engine speed |
|
TWRVSNMX2 |
delay time for time RVS monitoring of max limit 2 engine speed |
|
TWRVSPEDMX |
delay time for RVS monitoring of max. accelerator pedal position |
|
TWRVSPOLMN |
delay time for time RVS monitoring of low oil pressure |
|
TWRVSVFZG |
de-bouncing time vehicle speed to high for RVS |
|
TWSKWATMMX |
max.time for heat.flow requirement for faster reach Taupunktende |
|
TWSTT |
threshold soak time for re-start |
|
TWSVSENA |
Waiting period from INI f. SVS OFF onwards, at blink code output |
|
TWSVSINI |
Waiting period from INI f. SVS OFF onwards, at empty fault memory |
|
TWSVSINIF |
Waiting period from INI f. SVS OFF onwards, at stored fault |
|
TWSVSPC |
Waiting period f. pause between 2 complete blink codes |
|
TWSVSPS |
Waiting period f. 1st pause at the start of the blink code output |
|
TWSVSPZ |
Waiting period f. pause between 2 digits within a blink code |
|
TWSVSST |
Waiting period after engine start f. SVS OFF, at empty fault memory |
|
TWSVSSTF |
Waiting period after engine start f. SVS OFF, at stored fault |
|
TWTEFBPW |
waiting time for switching filter time contants of band filter (word) |
|
TWTMNHST |
waiting time for max.-range check of TMOT following hot soak start |
|
TWTPEAPFSO |
Representative wall temperature for heat-quantity calculation middle sensor |
|
TWTPEAPHSO |
Representative wall temperature for heat-quantity calculation downstream sensor |
|
TWTPEAPVSO |
Representative wall temperature for heat-quantity calculation upstream sensor |
|
TZ2FGRGA |
double numerator time constant for cruise control |
|
TZPUPVDG |
Time delay for zyklus from comparison with boost pressure |
|
TZPUPVDG |
Time delay for zyklus from comparison with boost pressure |
|
TZSPINI |
Resting time for filter initialisation |
|
T_BEISFE |